Massey Ferguson E1076.05 – Engine Control Unit (ECU): Voltage Issue On Fuel Solenoid On High Pressure Pump
Issue description
The control module has detected an open circuit or abnormal voltage condition on the actuator wires for the fuel injection pump's fuel control valve (fuel metering valve, suction control valve, or M-Prop). When this circuit is open, the engine will typically fail to start or run properly because rail pressure cannot be regulated.
Applies to these machines
25 machines- 7616
- 5612
- 7622
- Interim Tier 4 (2012-2015)
- 7614
- 5611
- 7615
- 5610
- 5613
- 7620
- 5609
- 7618
- 5608
- 7619
- 7626
- 7624
- 4707
- 4708
- 4709
- 4710
- 5710SL
- 5711SL
- 5712SL
- 5713SL
- 7714 through 7726S
Check the cause
Inspect the wiring harness from the high-pressure fuel pump solenoid back to the ECU for chafed wires, breaks, or areas where the harness may have rubbed against the engine block.
Disconnect the plug at the fuel solenoid and the ECU connector to inspect the pins for corrosion, pushed-back terminals, or loose connections.
Use a multimeter to check the continuity of the two actuator wires between the ECU and the solenoid to test for an open circuit.
Measure the resistance across the pins of the fuel solenoid itself. If the multimeter reads infinite resistance (OL), the internal coil has failed open and the valve must be replaced.
Repair steps
Clean the Area
Locate the high-pressure fuel pump on the engine. Thoroughly clean the pump housing and the area around the fuel metering solenoid to prevent any dirt or debris from entering the sensitive high-pressure pump.
Disconnect
Unplug the electrical connector from the fuel solenoid.
Remove the Solenoid
Remove the mounting fasteners (usually Torx or Allen bolts) securing the solenoid to the pump body. Carefully twist and pull the solenoid straight out of the pump housing.
Install the New Valve
Lubricate the O-rings on the new fuel pressure valve with clean diesel fuel. Gently insert it into the pump housing, ensuring the O-rings do not pinch or tear.
Torque
Install the mounting bolts and tighten them to the OEM specified torque.
Reconnect and Prime
Reconnect the electrical harness. Turn the key to the ON position to allow the electric lift pump to prime the low-pressure fuel circuit and purge air.
Clear Codes
Use a diagnostic scan tool to clear the E1076.05 code from the ECU, then start the tractor and verify that target fuel rail pressure is achieved and the code does not return.
Parts you might need
(2)Fuel Pressure Valve / Fuel Metering Valve / Fuel Solenoid
V837069409Fits a wide range of AGCO Power/Sisu engines used in Massey Ferguson 5400, 6400, 7400, 7600, 7700, 8600, and 8700 series tractors.
High-Pressure Fuel Pump Assembly
V837069146If the entire pump requires replacement
Get help to fix this fault by requesting a quote