Massey Ferguson E168.04 – Engine Electronic Module (EEM): Battery Voltage Below Normal / Battery Voltage Low
Issue description
The voltage level of the unswitched power supply to the controller is below the normal operating threshold. Depending on the exact system state, the controller triggers this fault when the supply voltage drops below 7.8V or 6.5V on a 12V system.
Applies to these machines
21 machines- 7616
- 5612
- 7622
- Interim Tier 4 (2012-2015)
- 7614
- 5611
- 7615
- 5610
- 5613
- 7620
- 5609
- 7618
- 5608
- 7619
- 7626
- 7624
- MF 5600 Series
- MF 6600 Series
- MF 6700 Series
- MF 7700 Series
- MF 8700 Series
Check the cause
Check battery state of charge and perform a load test (resting voltage should be ~12.6V)
Measure alternator output voltage across battery terminals with the engine running (should be 13.5V - 14.5V)
Inspect the wiring path from the battery to the EEM for bad contacts, corrosion, or chafed wires causing a voltage drop
Inspect and clean the main chassis ground and the ECU ground pins
Repair steps
Clean Connections
Disconnect the negative battery terminal, followed by the positive. Clean the battery posts and terminals with a wire brush. Reconnect and tighten them securely.
Test/Replace the Battery
If the battery fails a load test or will not hold a charge above 12.4V, remove the battery hold-down bracket, extract the old battery, and install a new OEM-spec battery.
Test/Replace the Alternator
If the battery is good but the running voltage is low, disconnect the battery, remove the serpentine/drive belt from the alternator pulley, disconnect the electrical connectors on the rear of the alternator, and unbolt it from the engine bracket. Install the new alternator, re-tension the belt, and reconnect the wiring.
Repair ECU Harness
If both the battery and alternator test fine, use a multimeter to measure the voltage directly at the EEM supply pins. If the voltage at the ECU is significantly lower than at the battery, locate and repair the corroded wire or replace the damaged section of the wiring harness.
Clear Codes
Turn the key to the ON position and use a diagnostic service tool to clear the E168.04 / SPN 168 FMI 4 fault code from the EEM.
Parts you might need
(5)Battery (OEM AGCO)
3933411M1Alternatively, a standard 12V agricultural battery matching the CCA/Ah requirements of your specific model
Negative Battery Terminal
4276409M1Alternator (175 Amp)
4287015M1Fits MF 6400, 7400, 7600 series
Alternator (175 Amp)
4287015M2Fits MF 6400, 7400, 7600 series
Alternator (120A / 180A)
4357550M3Fits MF 5600, 6600, 7600, 7700, 8700 series
Get help to fix this fault by requesting a quote