Massey Ferguson 3235.03 – Engine Control Unit (ECU): NOx Sensor Outlet SCR Signal Issue. (ECU)
Issue description
The Engine Control Unit (ECU) has detected an issue with the signal from the NOx sensor located at the outlet of the Selective Catalytic Reduction (SCR) system. The voltage from the sensor is outside of its expected range, erratic, or missing entirely. This affects the proper functioning of the emissions control system, as the ECU relies on this data to verify SCR efficiency and adjust Diesel Exhaust Fluid (DEF) dosing.
Applies to these machines
44 machines- 4710
- 7724S
- 5712SL
- 7722S
- 7722
- 5713SL
- 7720S
- 7716
- 7718
- T4
- 7715
- 5710SL
- 7726
- 4708
- 7726S
- 4707
- 4709
- 5711SL
- 7718S
- 7719
- 7714
- 7716S
- T4 (2015-2021)
- 7720
- Tier 4 (2015-2021)
- 7715S
- 7724
- 5608
- 5609
- 5610
- 5611
- 5612
- 5613
- 7614
- 7615
- 7616
- 7618
- 7619
- 7620
- 7622
- 7624
- 7626
- 7714S
- 7719S
Check the cause
Inspect the wiring harness and connector for the SCR Outlet NOx sensor for corrosion, pin-back, or wires chafing against hot exhaust components
Check the signal wire resistance (a resistance above 0.5 ohms indicates a wiring fault)
Measure the resistance across the heater pins with the sensor disconnected and cold (should typically be between 2 and 6 ohms)
Use a diagnostic tool to monitor live NOx ppm values; if the reading is frozen at 0 ppm or maxed out while the engine is running and warmed up, the sensor element has failed
Ensure the DEF fluid is not contaminated and that the SCR catalyst is not saturated with ammonia (ammonia slip), which can trick the sensor into reading high NOx levels
Repair steps
Preparation
Turn off the engine, apply the parking brake, and disconnect the batteries to prevent electrical shock. Ensure the exhaust system has cooled down.
Removal
Locate the SCR Outlet NOx sensor downstream of the SCR catalyst. Disconnect the electrical connector from the ECU/harness. Cut any zip-ties securing the sensor's wiring harness.
Extract the Sensor
Use a specialized slotted O2/NOx sensor socket to carefully unscrew the sensor from the exhaust pipe.
Preparation of New Sensor
Apply a small amount of anti-seize compound to the threads of the new NOx sensor (many new OEM sensors come with this pre-applied). Caution: Do not over-apply, as excess anti-seize can contaminate the sensor tip.
Installation
Thread the new sensor into the exhaust pipe and torque it to the OEM specification (typically around 50 N·m or 37 lb·ft).
Reconnection
Reconnect the electrical connector. Secure the wiring harness with zip-ties, ensuring it is routed exactly like the factory setup to avoid heat soak and vibration damage.
Calibration
Reconnect the batteries. Use a diagnostic tool to clear the fault codes. Note: Many modern Euro 6 / Tier 4 systems require variant coding or calibration of the new NOx sensor via the diagnostic tool; skipping this may cause the fault code to persist.
Parts you might need
(8)- NOx Sensor (Outlet / Downstream SCR)ACW1305320
Ensure you are purchasing the Outlet/Downstream sensor, as Inlet and Outlet sensors have unique CAN identification numbers and cannot be swapped. Typically manufactured by Continental (5WK9 series) or Bosch (0281008262/263).
NOx Sensor (Outlet / Downstream SCR)
ACW1813980Ensure you are purchasing the Outlet/Downstream sensor.
- NOx Sensor (Outlet / Downstream SCR)ACX248097A
Ensure you are purchasing the Outlet/Downstream sensor.
- NOx Sensor (Outlet / Downstream SCR)ACX2480970
Ensure you are purchasing the Outlet/Downstream sensor.
- NOx Sensor (Outlet / Downstream SCR)V837084094
Ensure you are purchasing the Outlet/Downstream sensor.
- NOx Sensor (Outlet / Downstream SCR)F835970020021
Often cross-listed with Fendt/AGCO applications. Ensure you are purchasing the Outlet/Downstream sensor.
- NOx Sensor, Outlet3978472M1
OEM AGCO part. Verify fitment by VIN.
- NOx Sensor, OutletV837070201
OEM AGCO part. Verify fitment by VIN.
Get help to fix this fault by requesting a quote