Massey Ferguson 521018.31 – Engine ECU: SCR NOx Levels Too High (ECU)
Issue description
This fault code indicates that the Selective Catalytic Reduction (SCR) system is failing to reduce Nitrogen Oxide (NOx) emissions to acceptable levels. The downstream NOx sensor is detecting higher-than-expected NOx concentrations exiting the tailpipe compared to the upstream sensor's readings. This typically triggers an engine derate (limp mode) to protect the environment and comply with emissions regulations.
Applies to these machines
41 machines- 4710
- 7724S
- 5712SL
- 7722S
- 7722
- 5713SL
- 7720S
- 7716
- 7718
- T4
- 7715
- 5710SL
- 7726
- 4708
- 7726S
- 4707
- 4709
- 5711SL
- 7718S
- 7719
- 7714
- 7716S
- T4 (2015-2021)
- 7720
- Tier 4 (2015-2021)
- 7715S
- 7724
- 5608
- 5609
- 5610
- 5611
- 5612
- 5613
- 5709
- 5710
- 5711
- 5713
- 7717
- 7721
- 7723
- 7725
Check the cause
DEF / AdBlue Quality Check: Contaminated fluid (dirt, water, or diesel) is a leading cause of SCR inefficiency. Check the DEF tank for debris and test the fluid concentration (it should be exactly 32.5% urea).
Live Data Monitoring: Use a diagnostic tool to monitor the upstream (pre-catalyst) and downstream (post-catalyst) NOx sensors. If the downstream sensor's readings do not drop under load, or if the sensor is stuck at a static value, the sensor is likely drifting or failing.
Inspect the DEF Dosing Module (Injector): Remove the DEF injector from the exhaust pipe and inspect it for severe urea crystallization, clogging, or fouling.
Check DEF Pump and Lines: Ensure the DEF pump is building adequate pressure and that there are no kinks, leaks, or damaged O-rings in the heated supply lines.
Repair steps
Resolve Fluid Issues
If the DEF is contaminated or degraded, drain the tank completely, flush the system, replace the DEF pump filter/strainer, and refill with fresh AUS-32 DEF.
Clean or Replace the Dosing Module
If the DEF injector is caked in crystallized urea, clean it using warm distilled water. If it is seized or electronically failed, replace the dosing module.
Replace Faulty NOx Sensor(s)
If live data confirms a sensor is reading out of range (often caused by heat degradation or soot contamination), replace the affected NOx sensor.
System Reset and Adaptation
After replacing the NOx sensor or dosing module, you must use a compatible diagnostic tool (e.g., dealer tool or advanced aftermarket tool like TOPDON Phoenix Elite) to clear the fault codes and perform an SCR system reset/NOx sensor adaptation. The code will not clear on its own just by replacing the part.
Parts you might need
(9)NOx Sensor (Upstream/Downstream depending on fitment)
V837084094OEM Part
NOx Sensor (Upstream/Downstream depending on fitment)
ACW1305320OEM Part
NOx Sensor (Upstream/Downstream depending on fitment)
65117OEM Part
NOx Sensor (Upstream/Downstream depending on fitment)
ACX248097AOEM Part
NOx Sensor (Upstream/Downstream depending on fitment)
0281008262Bosch Part
NOx Sensor (Upstream/Downstream depending on fitment)
0281008263Bosch Part
DEF Dosing Module / Urea Injector
V837072107OEM Part
DEF Dosing Module / Urea Injector
V837074845OEM Part
DEF Dosing Module / Urea Injector
0444023011Bosch Part
Get help to fix this fault by requesting a quote