Massey Ferguson 626.06 – Engine Control Unit (ECU): Engine Intake Heater High Amps
Issue description
Grid heater relay current above normal or short to GROUND. The engine controller has detected an excessive current draw on the control circuit for the intake manifold grid heater relay, which almost always indicates a short circuit to ground in the relay itself or the wiring harness.
Applies to these machines
45 machines- 4710
- 7724S
- 5712SL
- Interim Tier 4 (2012-2015)
- 7722
- 7722S
- 7615
- 5613
- 5713SL
- 7720S
- 7716
- 7718
- T4
- 7715
- 5710SL
- 7726
- 7616
- 7618
- 5608
- 4708
- 7619
- 7626
- 7726S
- 7624
- 4707
- 4709
- 5711SL
- 7614
- 7718S
- 5610
- 7620
- 7719
- 7714
- 7716S
- T4 (2015-2021)
- 5612
- 7622
- 7720
- Tier 4 (2015-2021)
- 5611
- 7715S
- 5609
- 7724
- 7714S
- 7719S
Check the cause
Inspect the grid heater relay terminals for melting, arcing, or severe corrosion
Test the relay coil resistance using a multimeter to check for an internal short or continuity to the relay casing
Check the wiring harness between the ECU and the relay block for chafed, pinched, or melted insulation causing a short to ground
Inspect the heavy-gauge power cable running from the relay to the intake manifold grid heater element to ensure it hasn't rubbed through and shorted against the engine block
Repair steps
Disconnect battery
Turn off the ignition and disconnect the negative battery cable.
Locate relay
Locate the grid heater relay. Depending on the model, this is usually found in the engine compartment relay box or mounted near the starter motor.
Repair wiring harness
If the wiring harness is damaged and shorting to ground, cut out the damaged section, solder in a new piece of wire, seal it with heat-shrink tubing, and re-loom the harness.
Replace relay
If the wiring is intact, the relay is likely internally shorted. Remove the faulty 70-Amp relay and plug in the replacement.
Reconnect battery
Reconnect the battery.
Reset system
To clear the code without a service tool, perform an EEM4 system reset by turning the ignition OFF for a minimum of 60 seconds, then turning it back ON. Alternatively, use an AGCO diagnostic service tool to clear the inactive fault.
Verify repair
Start the tractor and verify the code does not return during the cold-start pre-heating cycle.
Parts you might need
(3)Grid Heater Relay / Starter Relay (70 Amp, 4-Pin)
57115Fits Massey Ferguson 5600, 7600, and 7700 series, as well as Valtra equivalents.
Grid Heater Relay / Starter Relay (70 Amp, 4-Pin)
ACW0933610Fits Massey Ferguson 5600, 7600, and 7700 series, as well as Valtra equivalents.
Engine Intake Manifold Heater / Grid Heater Element
Generic part name. Only replace if the element itself is physically shorted to its housing.
Get help to fix this fault by requesting a quote