Massey Ferguson 729.03 – Engine Control Unit (ECU): Engine Intake Heater High Voltage (ECU)
Issue description
The measured voltage on the intake air heater (grid heater) circuit is above the normal operating range. This typically indicates that the grid heater wiring is shorted to a high voltage source, the grid heater relay is defective (stuck ON), or the grid heater itself has failed.
Applies to these machines
44 machines- 4710
- 7724S
- 5712SL
- Interim Tier 4 (2012-2015)
- 7722
- 7722S
- 7615
- 5613
- 5713SL
- 7720S
- 7716
- 7718
- T4
- 7715
- 5710SL
- 7726
- 7616
- 7618
- 5608
- 4708
- 7619
- 7626
- 7726S
- 7624
- 4707
- 4709
- 5711SL
- 7614
- 7718S
- 5610
- 7620
- 7719
- 7714
- 7716S
- T4 (2015-2021)
- 5612
- 7622
- 7720
- Tier 4 (2015-2021)
- 5611
- 7715S
- 5609
- 7724
- 6713
Check the cause
Clear the code first: save the error log, erase it, and restart the ECU to rule out a transient voltage spike
Inspect the intake air heater relay and its electrical connections for damage, corrosion, or being stuck in the closed (ON) position
Inspect the grid heater wiring harness for defects, specifically looking for a short to a high voltage source
Check shared wiring: the intake air heater signal circuit shares wiring with the intake manifold pressure/temperature sensor, camshaft position sensor, water-in-fuel sensor, and rail fuel pressure sensor
Repair steps
Access components
Turn off the engine and remove the engine hood assembly to access the intake manifold and relay block.
Locate relay
Locate the intake air heater relay (usually found on the main fuse/relay block or near the intake manifold).
Test and replace relay
Remove the relay cover and use a multimeter to test the relay for continuity. If the relay is stuck closed (providing constant high voltage to the heater), replace the relay.
Inspect and repair wiring
If the relay is functioning correctly, trace the wiring from the relay to the intake air heater (grid heater) on the intake manifold. Repair or replace any sections of the harness that are melted, chafed, or shorted to power.
Replace intake air heater
If the wiring and relay are both intact and functioning properly, the fault lies within the intake air heater itself. Remove the intake hose and electrical connections to the grid heater, unbolt it from the intake manifold, and install a replacement unit.
Verify repair
Clear the fault codes via the diagnostic port and run the engine to verify the repair.
Parts you might need
(5)Intake Air Heater Relay
5711570 Amp, 4-pin relay. Fits Massey Ferguson 5400, 5600, 6600, 6700, 7600, and 7700 series.
Intake Air Heater Relay
ACW093361070 Amp, 4-pin relay. Fits Massey Ferguson 5400, 5600, 6600, 6700, 7600, and 7700 series.
Intake Air Heater (Grid Heater)
F718202180010AGCO Grid Heater, For Intake Air
Intake Air Heater (Grid Heater)
ACX2840180Listed for MF 6713
Intake Air Heater (Grid Heater)
2666108Perkins Genuine 12V Grid Heater
Get help to fix this fault by requesting a quote