9174

Massey Ferguson 9174: MPROP Control Open Circuit

Issue description

The system has detected an open circuit in the MPROP control. This indicates a break or disconnection in the wiring or connection associated with the MPROP control.

Check the cause

  1. MPROP control wiring

  2. MPROP control connections

  3. MPROP control itself

Repair steps

  1. Inspect

    Inspect the wiring and connections related to the MPROP control for any visible damage, disconnection, or corrosion.

  2. Test

    Test the continuity of the wiring and connections to the MPROP control using a multimeter or appropriate testing equipment.

  3. Repair or Replace

    Repair or replace any damaged wiring, connections, or the MPROP control as necessary to restore proper functionality.

Parts you might need