E977.03

Massey Ferguson E977.03 – ECU: Engine Cooling Fan Speed Solenoid Issue

Issue description

Fan control Output in short circuit (short circuit to a higher voltage source / +12V).

Applies to these machines

  • 7616
  • 5612
  • 7622
  • Interim Tier 4 (2012-2015)
  • 7614
  • 5611
  • 7615
  • 5610
  • 5613
  • 7620
  • 5609
  • 7618
  • 5608
  • 7619
  • 7626
  • 7624
  • 4707
  • 4708
  • 4709
  • 4710
  • 5710SL
  • 5711SL
  • 5712SL
  • 5713SL
  • 7714
  • 7726S

Check the cause

  1. Check the wiring harness running from the ECU to the engine cooling fan speed solenoid for rubbed, melted, or pinched wires causing a short to power (+12V).

  2. Disconnect the fan control solenoid and ECU connectors to inspect pins for corrosion, pushed-back terminals, or moisture ingress.

  3. Measure the internal resistance of the fan speed solenoid to see if it reads as a dead short, indicating internal failure.

Repair steps

  1. Disconnect Power

    Turn off the ignition and disconnect the negative battery cable to protect the ECU/EEM from voltage spikes.

  2. Access the Fan Drive

    Locate the cooling fan speed solenoid, which is typically mounted on or integrated into the electronic viscous fan drive assembly at the front of the engine.

  3. Isolate the Short

    Disconnect the solenoid. Use a multimeter to test the harness side for continuity to power.

  4. Repair Wiring (If Applicable)

    If the harness is shorted, splice and repair the damaged section of the wiring loom, then wrap it in high-heat protective loom.

  5. Replace the Solenoid/Fan Drive (If Applicable)

    If the wiring tests good, the short is internal to the solenoid. Remove the mounting bolts securing the fan control solenoid (or the entire viscous fan clutch assembly, depending on whether the solenoid is serviceable separately) and install the new component.

  6. Reassemble and Clear Codes

    Reconnect the electrical pigtail, reconnect the battery, and start the tractor. Allow the engine to reach operating temperature to verify that the fan engages properly and the E977.03 code changes to an inactive state or clears entirely.

Parts you might need

(1)
  • Engine Cooling Fan Speed Solenoid / Visctronic Fan Control Module

    May require replacement of the complete Electronic Viscous Fan Drive / Fan Clutch Assembly depending on the engine. Reference specific tractor's serial number.