A.40.11

Massey Ferguson A.40.11: External Hydraulic Valve 4 Issue

Issue description

Malfunction associated with the 4th external hydraulic remote valve (spool valve). The underlying condition is typically an electrical connection problem on the hydraulic valve (open circuit, short circuit to earth, short circuit between cables, or current level error at the solenoid), or a mechanical failure preventing the valve from operating correctly or holding pressure.

Applies to these machines

  • 5710SL
  • 5711SL
  • 5712SL
  • 5713SL
  • T4
  • 4707
  • 4708
  • 4709
  • 4710
  • 5608
  • 5609
  • 5610
  • 5611
  • 5612
  • 5613
  • 7614
  • 7615
  • 7616
  • 7618
  • 7619
  • 7620
  • 7622
  • 7624
  • 7626
  • 7714
  • 7715
  • 7715S
  • 7716
  • 7716S
  • 7718
  • 7718S
  • 7719
  • 7720
  • 7720S
  • 7722
  • 7722S
  • 7724
  • 7724S
  • 7726
  • 7726S
  • 8670

Check the cause

  1. Check the hydraulic fluid level and condition. If the fluid is dark, smells burnt, or has a milky appearance (indicating water contamination), it must be addressed first.

  2. Inspect the wiring harness, connector, and pins at External Hydraulic Valve 4 for corrosion, open circuits, or short circuits.

  3. Use a hydraulic gauge to test the system pressure to determine if the issue is isolated to Valve 4 or if there is a broader pump/restriction issue.

  4. Check for external hydraulic leaks around the valve, couplers, and hoses, which can cause pressure drops.

  5. Ensure the hydraulic filter is not partially blocked, which restricts flow to the system.

Repair steps

  1. Fluid Maintenance

    If the hydraulic fluid is contaminated or degraded, flush the system and change the fluid.

  2. Wiring Repair

    If the diagnostic checks reveal a broken wire or corroded connector at Valve 4, repair or replace the damaged section of the wiring harness.

  3. Solenoid Replacement

    If the wiring is intact but the solenoid for Valve 4 has an internal short or open circuit, remove and replace the solenoid coil.

  4. Valve Servicing

    If the electrical components are functioning but the valve is leaking internally or sticking, remove the hydraulic control valve assembly.

  5. Seal Replacement

    Replace any worn O-rings, seals, or damaged check valves within the Valve 4 section. If the valve body is heavily scored, the entire valve section must be replaced.

  6. Reassembly

    Reinstall the valve, replace the hydraulic filter (recommended every 300–500 hours), and refill the system with clean UTTO fluid.

  7. Code Clearing

    Use a compatible Massey Ferguson diagnostic tool or interface device to clear the DTC from the system and test the remote connections for proper operation.

Parts you might need

(4)
  • External Hydraulic Valve 4 Solenoid / Spool Valve Assembly

    OEM Massey Ferguson

  • Hydraulic Filter

    OEM Massey Ferguson, or aftermarket equivalents like MANN-FILTER

  • Hydraulic Fluid (UTTO)

    Universal Tractor Transmission Oil (e.g., 10W40)

  • Hydraulic Seal Kit / O-rings

    For rebuilding the leaking control valve

Get help to fix this fault by requesting a quote

Browse other Massey Ferguson codes