A.62.22

Massey Ferguson A.62.22: External Hydraulic Valve 6 Issue

Issue description

Indicates a malfunction, connection problem, or failure within the circuit of the tractor's 6th external hydraulic remote valve.

Applies to these machines

  • 5710SL
  • 5711SL
  • 5712SL
  • 5713SL
  • T4
  • 4707
  • 4708
  • 4709
  • 4710
  • 5608
  • 5609
  • 5610
  • 5611
  • 5612
  • 5613
  • 7614
  • 7615
  • 7616
  • 7618
  • 7619
  • 7620
  • 7622
  • 7624
  • 7626
  • 7714
  • 7715
  • 7715S
  • 7716
  • 7716S
  • 7718
  • 7718S
  • 7719
  • 7720
  • 7720S
  • 7722
  • 7722S
  • 7724
  • 7724S
  • 7726
  • 7726S

Check the cause

  1. Check the hydraulic fluid (UTTO) level and condition. A hydraulic filter that is 70% contaminated will severely reduce oil flow and force the system to work harder.

  2. Check for aeration in the system (often occurring after filter replacements or hose repairs), which causes vibrations, spontaneous cylinder action, and erratic valve behavior.

  3. Inspect the external control valves, quick couplers, and wiring harnesses for Valve 6. Look for physical leaks, damaged seals, or disconnected electrical solenoids.

  4. Perform a manual valve test by manually moving the pump control valve lever back and forth to see if a stuck valve releases.

Repair steps

  1. Attempt Manual Release

    If the valve is physically stuck, try to release it by manually moving the control valve lever back and forth, or by repeatedly cycling the lift arms/remotes.

  2. Access the Valve Block

    If the valve remains unresponsive or the electrical fault persists, access the external hydraulic valve block.

  3. Remove and Clean/Replace

    Remove the specific control valve (Valve 6) from the assembly. Clean the valve chamber and inspect the internal seals and solenoids. If the valve or solenoid is burnt out or scored, it must be replaced.

  4. Flush and Filter

    If the failure was due to contamination, flush the contaminated hydraulic fluid from the system.

  5. Reassemble and Bleed

    Install the new valve, replace the hydraulic filter, and refill the system with fresh UTTO fluid. Bleed the system to ensure no air is trapped, which would cause further aeration issues.

Parts you might need

(4)
  • External Hydraulic Control Valve (Valve 6 / Spool Valve)

    Generic part; exact OEM number depends on the specific tractor chassis.

  • Hydraulic Filter

    OEM highly recommended. Using non-original aftermarket filters increases the risk of contamination entry by 35%.

  • Hydraulic Fluid (UTTO)

    e.g., 10W40, used to lubricate and power the system.

  • Hydraulic Pump

    Generic part; only requires replacement if the valve failure caused dead-heading and secondary pump damage.

Get help to fix this fault by requesting a quote