B.02.05

Massey Ferguson B.02.05 – Mid Mount Valve Module: Loader Mid Mount Electro Valve Solenoid Low Amp Draw

Issue description

The control module is detecting an electrical current (amperage) that is lower than the minimum required threshold when attempting to energize the loader's mid-mount electro-hydraulic valve solenoid, indicating high electrical resistance in the circuit.

Applies to these machines

  • 5710SL
  • 5711SL
  • 5712SL
  • 5713SL
  • T4
  • 5608
  • 5609
  • 5610
  • 5611
  • 5612
  • 5613
  • 4707
  • 4708
  • 4709
  • 4710
  • 7614-7626
  • 7714-7726S

Check the cause

  1. Visual Inspection: Locate the mid-mount valve block (usually mounted on the right side of the tractor frame below the cab) and inspect the wiring harness leading to the solenoids for chafing, rodent damage, or tight bends.

  2. Connector Check: Disconnect the plug at the affected solenoid. Check for dirt, water ingress, or green corrosion on the pins.

  3. Coil Resistance Test: Using a digital multimeter, measure the resistance (Ohms) across the two pins of the solenoid coil. A healthy 12V coil typically reads between 5 to 10 Ohms. If it reads 'OL' (Open Loop) or unusually high resistance, the coil is dead.

  4. Voltage Supply Test: With the connector unplugged, have an operator actuate the loader joystick in the cab (key ON, engine OFF). Measure the voltage at the harness connector to ensure the Mid Mount Valve Module is sending the correct voltage signal.

  5. Check for Related Codes: Look for spool position sensor codes (e.g., 0B.00.17 through 0B.00.21 or M17-M21) which could indicate a mechanical sticking issue in the valve spool rather than just an electrical coil failure.

Repair steps

  1. Power Down

    Turn off the tractor, remove the key, and disconnect the negative battery terminal to prevent short circuits.

  2. Clean the Area

    Thoroughly clean the exterior of the mid-mount valve block with brake cleaner or compressed air to prevent dirt from entering the hydraulic system.

  3. Disconnect Wiring

    Unplug the electrical connector from the faulty solenoid.

  4. Remove the Coil

    Remove the retaining nut or cap screw at the end of the solenoid cartridge.

  5. Slide Off the Coil

    Carefully slide the faulty electromagnetic coil off the valve stem. (Note: You do not need to open the hydraulic system or remove the valve cartridge itself, so no hydraulic fluid should leak).

  6. Inspect the Stem

    Ensure the valve stem is not bent, scored, or heavily rusted.

  7. Install New Coil

    Slide the new solenoid coil over the stem. Install and tighten the retaining nut (do not overtighten, as this can crack the plastic coil housing).

  8. Reconnect

    Plug the electrical connector back in, ensuring the weather seal clicks into place.

  9. Clear Codes & Test

    Reconnect the battery. Use a compatible diagnostic tool (or the dash interface) to clear the stored DTCs. Start the tractor and test the loader joystick in all directions to confirm the repair.

Parts you might need

(3)
  • Loader Mid Mount Electro Valve Solenoid Coil

    Generic OEM replacement

  • Spool Position Sensor

    Often replaced if codes M17-M21 are present alongside the amp draw code

  • Mid Mount Valve Module

    Only if the module fails to output voltage to a known-good wiring harness

Get help to fix this fault by requesting a quote

Browse other Massey Ferguson codes