Massey Ferguson D148 – Instrument Panel (DCC2 / X55): Instrument panel: Attempt to program with engine running
Issue description
A procedural/software error indicating that an attempt was made to flash, reprogram, or load a new software program into the dashboard while the tractor's engine was actively running.
Applies to these machines
20 machines- MF 8600
- MF 8650
- MF 8660
- MF 8670
- MF 8680
- MF 8690
- MF 8450
- MF 8460
- MF 8470
- MF 8480
- Massey Ferguson 8600 Series
- Massey Ferguson 8650
- Massey Ferguson 8660
- Massey Ferguson 8670
- Massey Ferguson 8680
- Massey Ferguson 8690
- Massey Ferguson 8400 Series
- Massey Ferguson 6400 Series
- Massey Ferguson 7400 Series
- Massey Ferguson 7000 Series (Dyna-6)
Check the cause
Verify if a technician recently connected a diagnostic laptop (such as AGCO EDT or Wintest) and attempted to update the dashboard software
Check if the operator or technician accidentally left the engine running during a software update
Ensure the dashboard is not suffering from a voltage supply drop or wiring short that might trick the DCC2 into entering a programming state
Repair steps
Stop the Engine
Turn off the tractor completely to halt the engine.
Set to Key-On, Engine-Off (KOEO)
Turn the ignition key to the "ON" position to supply power to the DCC2 instrument panel, but do not crank or start the engine.
Re-initiate Programming
Using your authorized diagnostic tool, restart the software flash/programming procedure for the DCC2.
Clear Codes
Once the software load is successfully completed, cycle the ignition key off, wait a few seconds, and then start the engine. Verify that fault code D148 has moved to an inactive state and clear it from the system memory.
Parts you might need
(6)Instrument Panel (DCC2)
3787409M97For MF 6400, 7400, 8400 Series
Instrument Panel (DCC2)
3787412M95For MF 6400, 7400, 8400 Series
Instrument Panel (DCC2) - Remanufactured Exchange
3787409E97For MF 6400, 7400, 8400 Series
Instrument Panel (DCC2) - Remanufactured Exchange
3787412E95For MF 6400, 7400, 8400 Series
Instrument Panel (DCC3)
4353089M92For MF 5600, 6600, 7600, 8600 Series
Instrument Panel (DCC3) - Remanufactured Exchange
4353089E92For MF 5600, 6600, 7600, 8600 Series
Get help to fix this fault by requesting a quote