Massey Ferguson E 9171 (6) – Engine Control Unit (ECU): Preheater control, short circuit to earth.
Issue description
The Engine Control Unit (ECU) has detected that the electrical circuit for the preheating system is shorted to ground. This occurs when a current-carrying wire makes an unintended connection with the vehicle's chassis or another grounded component, causing excessive current flow. This electrical fault disables or impairs the preheating system (glow plugs or thermostart intake heater), which is crucial for starting the diesel engine in cold conditions.
Applies to these machines
13 machines- 8600 Series
- 8650
- 8660
- 8670
- 8680
- 8690
- 5400 Series
- 5600 Series
- 6400 Series
- 6600 Series
- 6700 Series
- 7600 Series
- 7700 Series
Check the cause
Inspect the fuse box for a blown preheater control circuit fuse (often a 5A fuse, such as F16), which strongly indicates an active short to ground.
Trace the wiring harness from the Engine ECU to the preheater control relay. Look for chafed insulation, pinched wires, or exposed copper touching the tractor chassis or engine block.
Disconnect the 4-pin grid heater relay and use a multimeter to check for an internal short to ground on the control side of the relay.
Check the resistance of the intake air preheater element itself to ensure it has not internally shorted to its own grounded housing.
Repair steps
Disconnect Power
Turn off the ignition and disconnect the tractor's battery to prevent electrical spikes or accidental shorts during repair.
Access the Relay
Locate the preheater control relay (grid heater relay) in the engine bay electrical center or firewall.
Repair Wiring
If the diagnostic checks revealed a rubbed or pinched wire in the Sisu engine harness, cut out the damaged section, solder in a new piece of wire, and seal it with heat-shrink tubing. Secure the harness away from vibration points.
Replace the Relay
If the relay failed the multimeter test, remove the faulty 4-pin 70 Amp relay and plug in the OEM replacement.
Reassemble and Clear Codes
Reconnect the battery. Turn the ignition key to the ON position to allow the ECU to run its self-check. Use a diagnostic service tool (like the WinEEM3s Service Tool) to clear the E 9171 (6) fault code from the ECU memory.
Verify Operation
Cycle the key in cold conditions to ensure the preheater engages properly without the fault code returning.
Parts you might need
(16)Starter Motor / Grid Heater Relay (70 Amp, 4-Pin)
57115Starter Motor / Grid Heater Relay (70 Amp, 4-Pin)
ACW0933610- Preheater / Thermostart893501M91
For various models with Perkins engines
- Relay3615652M1
For a wide range of models
- RelayV837069047
5-Pin Relay
7066359M91For many compact and utility tractors
- 12V Relay4272432M1
- Solenoid3619763M1
Solenoid
1025381M91For Delco starters
Solenoid
1047083M91For Delco starters
Solenoid
1094962M91For Delco starters
Solenoid
1755027M91For Delco starters
- Heater Control Valve3907312M1
Thermostart Intake Manifold Heater/Glow Plug
1446935M1Replaces 3583543M1, 2666108, 3583543M2. Common component for many Massey Ferguson models.
Preheater Control Relay / Grid Heater Relay
7073150M91
Get help to fix this fault by requesting a quote