E 9171 (6)

Massey Ferguson E 9171 (6) – Engine Control Unit (ECU): Preheater control, short circuit to earth.

Issue description

The Engine Control Unit (ECU) has detected that the electrical circuit for the preheating system is shorted to ground. This occurs when a current-carrying wire makes an unintended connection with the vehicle's chassis or another grounded component, causing excessive current flow. This electrical fault disables or impairs the preheating system (glow plugs or thermostart intake heater), which is crucial for starting the diesel engine in cold conditions.

Applies to these machines

  • 8600 Series
  • 8650
  • 8660
  • 8670
  • 8680
  • 8690
  • 5400 Series
  • 5600 Series
  • 6400 Series
  • 6600 Series
  • 6700 Series
  • 7600 Series
  • 7700 Series

Check the cause

  1. Inspect the fuse box for a blown preheater control circuit fuse (often a 5A fuse, such as F16), which strongly indicates an active short to ground.

  2. Trace the wiring harness from the Engine ECU to the preheater control relay. Look for chafed insulation, pinched wires, or exposed copper touching the tractor chassis or engine block.

  3. Disconnect the 4-pin grid heater relay and use a multimeter to check for an internal short to ground on the control side of the relay.

  4. Check the resistance of the intake air preheater element itself to ensure it has not internally shorted to its own grounded housing.

Repair steps

  1. Disconnect Power

    Turn off the ignition and disconnect the tractor's battery to prevent electrical spikes or accidental shorts during repair.

  2. Access the Relay

    Locate the preheater control relay (grid heater relay) in the engine bay electrical center or firewall.

  3. Repair Wiring

    If the diagnostic checks revealed a rubbed or pinched wire in the Sisu engine harness, cut out the damaged section, solder in a new piece of wire, and seal it with heat-shrink tubing. Secure the harness away from vibration points.

  4. Replace the Relay

    If the relay failed the multimeter test, remove the faulty 4-pin 70 Amp relay and plug in the OEM replacement.

  5. Reassemble and Clear Codes

    Reconnect the battery. Turn the ignition key to the ON position to allow the ECU to run its self-check. Use a diagnostic service tool (like the WinEEM3s Service Tool) to clear the E 9171 (6) fault code from the ECU memory.

  6. Verify Operation

    Cycle the key in cold conditions to ensure the preheater engages properly without the fault code returning.

Parts you might need

(16)
  • Starter Motor / Grid Heater Relay (70 Amp, 4-Pin)

    57115
  • Starter Motor / Grid Heater Relay (70 Amp, 4-Pin)

    ACW0933610
  • For various models with Perkins engines

  • Relay3615652M1

    For a wide range of models

  • RelayV837069047
  • 5-Pin Relay

    7066359M91

    For many compact and utility tractors

  • 12V Relay4272432M1
  • Solenoid3619763M1
  • Solenoid

    1025381M91

    For Delco starters

  • Solenoid

    1047083M91

    For Delco starters

  • Solenoid

    1094962M91

    For Delco starters

  • Solenoid

    1755027M91

    For Delco starters

  • Thermostart Intake Manifold Heater/Glow Plug

    1446935M1

    Replaces 3583543M1, 2666108, 3583543M2. Common component for many Massey Ferguson models.

  • Preheater Control Relay / Grid Heater Relay

    7073150M91

Get help to fix this fault by requesting a quote

Browse other Massey Ferguson codes