U 1761 (4)

Massey Ferguson U 1761 (4) – Engine Control Unit (ECU) - EEM3: Urea Tank Level Sensor error: Signal below lower limit

Issue description

This indicates an electrical fault where the supply voltage signal to the Diesel Exhaust Fluid (DEF) / Urea tank level sensor is outside of its expected operating range. This is typically caused by a short circuit to the battery (voltage too high), a short circuit to ground (voltage too low), an open circuit in the wiring harness, or an internal failure of the sensor itself.

Applies to these machines

  • 8600 Series
  • 8650
  • 8660
  • 8670
  • 8680
  • 8690
  • 5700 Series
  • 6700 Series
  • 7700 Series

Check the cause

  1. Visual Fluid Check: Physically verify the actual fluid level in the DEF/AdBlue tank to ensure the tank is not completely empty, which could cause erratic sensor readings.

  2. Wiring and Connector Inspection: Inspect the wiring harness leading to the DEF tank sensor. Look for chafed wires rubbing against the chassis (which causes a short to ground) and check the connector for water ingress, corrosion, or bent pins.

  3. Voltage Test: Using a multimeter, disconnect the sensor and check the harness side for proper reference voltage (usually 5V) and a good ground. If the reference voltage is missing, the issue is in the wiring harness or ECU, not the sensor.

  4. Contamination Check: Inspect the tank for DEF crystallization or dirt contamination, which can damage the sensor float or probes.

Repair steps

  1. Preparation

    Turn off the tractor, remove the key, and disconnect the battery to prevent electrical shorts.

  2. Clean the area

    Thoroughly clean the top of the DEF tank around the sensor/header module. DEF systems are highly sensitive to contamination; no dirt or debris can be allowed to fall into the tank.

  3. Disconnect electricals

    Unplug the electrical wiring harness connector from the DEF level sensor.

  4. Disconnect fluid lines

    Carefully disconnect the DEF supply and return lines from the sensor header. Have a clean rag ready to catch spills, as DEF is corrosive and will crystallize when exposed to air.

  5. Remove the sensor

    Unscrew the retaining ring or mounting bolts securing the sensor assembly to the tank. Carefully pull the old sensor unit straight up and out of the tank.

  6. Install the new sensor

    Insert the new DEF level sensor assembly into the tank. Ensure the new O-ring or rubber gasket is properly seated to prevent fluid leaks and keep dirt out.

  7. Reassembly

    Secure the retaining ring or bolts. Reconnect the DEF fluid lines (ensuring quick-connects click into place) and plug in the electrical connector.

  8. Clear codes

    Reconnect the battery, turn on the ignition, and use a diagnostic scan tool to clear the U 1761 (4) fault code from the ECU. Run the machine to verify the DEF gauge reads correctly and the code does not return.

Parts you might need

(7)
  • DEF Sensor

    ACW0251030
  • DEF Sensor Tank / Fuel Level Sender

    ACW288799A
  • DEF Sensor / Fuel Level Indicator Sensor

    ACW288801A
  • DEF Sensor

    ACW212632A
  • DEF Sensor Kit / Fuel Level Sender

    ACW288799C

Get help to fix this fault by requesting a quote

Browse other Massey Ferguson codes