X174

Massey Ferguson X174 – Massey Ferguson Linkage: No CAN Unlocking Signal from EXT Lite Transmission Controller

Issue description

The EXT Lite transmission controller is not providing a CAN unlocking signal, which may prevent proper communication or operation of the Dyna-VT transmission.

Check the cause

  1. The connection between the EXT Lite transmission controller and the Dyna-VT transmission

  2. The power supply to the EXT Lite transmission controller

  3. The integrity of the CAN bus wiring related to the transmission controller

Repair steps

  1. Inspect

    Check the physical connections between the EXT Lite transmission controller and the Dyna-VT transmission for looseness, damage, or corrosion.

  2. Verify

    Confirm that the power supply to the EXT Lite transmission controller is stable and meets the required specifications.

  3. Test

    Use a diagnostic tool to check the CAN bus communication for any faults or disruptions related to the transmission controller.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other Massey Ferguson codes