Valtra 2327 – Aftermarket ISOBUS or autosteering controller: Claas ATP - Not Ready for Work
Issue description
This fault code indicates a communication issue with a component of an aftermarket autosteering system, rather than a native Valtra system fault. The main controller of the autosteering system (such as a Reichhardt GREEN FIT unit) is unable to establish a proper connection with the Claas ATP module. The connection to the ATP module is incomplete or has been interrupted, preventing the system from being ready for use.
Applies to these machines
1 machine- Valtra tractors equipped with a third-party autosteering or guidance system
Check the cause
Verify the autosteering controller is correctly configured for the specific machine and components, especially if components were recently moved between machines
Inspect the wiring harness between the main controller and the Claas ATP module for any signs of damage, chafing, or corrosion
Locate the Claas ATP module (often behind an access panel to the right of the driver's seat), disconnect and reconnect the main 6-pin electrical connector, and check for bent or pushed-out pins
Check the integrity of the CAN bus wiring and connections for general communication errors
Verify that the autosteering controller and the ATP module are receiving the correct voltage and have a solid ground connection
Access the diagnostics menu on the autosteering system's display terminal to check for specific communication failure messages, such as 'no GMS message' (fault 2328) or 'no life message' (fault 2329)
Repair steps
Power cycle the system
Turn off the tractor and the autosteering system completely. Wait for a few minutes before restarting to see if the communication error resolves itself.
Perform physical wiring checks
Systematically go through the physical wiring and connector integrity checks between the main controller and the Claas ATP module to rule out a physical disconnect.
Check for software updates
Ensure the autosteering controller (e.g., Reichhardt GREEN FIT) has the latest software version installed, as outdated software can cause compatibility issues.
Isolate the fault
If possible, test the ATP module or the main controller on another compatible machine to determine which specific component is faulty.
Contact technical support
If the fault persists after checking all connections and configurations, contact the support line for the autosteering system manufacturer (e.g., Reichhardt) for specific diagnostic guidance based on the vehicle code and system setup.
Replace the Claas ATP module
If the Claas ATP module is identified as the faulty component, it will need to be replaced. Note that this module is generally considered a non-repairable part.
Parts you might need
(6)Claas ATP Module
B695Listed by Ilgenfritz Mechatronics as a non-repairable part. Confirm fitment before ordering.
Claas Auto Pilot Module
0112310Known Claas autosteering component; may be the ATP module under a different name.
Claas Auto Pilot Module
0112311Known Claas autosteering component; may be the ATP module under a different name.
Generic Claas Control Module
0145371Function as ATP module unconfirmed.
Generic Claas Control Module
014643Function as ATP module unconfirmed.
Generic Claas Control Module
149050Function as ATP module unconfirmed.
Get help to fix this fault by requesting a quote