Valtra 2335 – Main Control Unit: CAN Bus Communication Error
Issue description
A communication error indicates that one or more control modules are not sending or receiving data correctly across the CAN bus network. This failure prevents critical information from being shared between electronic control units, such as the engine ECU, hydraulic brake module (HBM), or main vehicle controller, potentially leading to system malfunctions or loss of drive display data.
Applies to these machines
21 machines- N Series
- T Series
- F Series
- Lexion 400 Series
- Lexion 5000 Series
- Lexion 6000 Series
- Lexion 7000 Series
- Lexion 480R
- Lexion 500 Series
- Lexion 540R
- Lexion 560
- Lexion 560R
- Lexion 570
- Lexion 570R
- Lexion 575R
- Lexion 580R
- Lexion 585R
- Lexion 590R
- Lexion 595R
- Lexion 550
- Lexion 580
Check the cause
Review Fault Codes: Use the tractor's diagnostic system to read all active and stored fault codes (e.g., Valtra code 006304 03 040)
Check battery voltage (voltage below 11.5V can cause communication issues)
Inspect the fuse cabinet for corrosion, dampness, or debris
Inspect wiring harnesses and connectors for damage (e.g., rodent damage), poor contacts, or disconnected wires on selectors and sensors
Perform a CAN bus resistance check with power off (should read approximately 60 Ohms between CAN High and CAN Low; 120 Ohms indicates a missing termination resistor, while lower than 60 Ohms suggests a short circuit or extra terminator)
Perform a CAN bus voltage check with power on and network idle (CAN High should be 2.5V-3.5V, CAN Low should be 1.5V-2.5V)
Inspect specific modules like the HBM, engine ECU, and hydraulic pump for damage or corrosion
Repair steps
Address basic electrical issues
Rectify any visible wiring damage, clean corrosion on fuses or connectors, and ensure all connections are secure. Verify battery voltage is above 11.5V.
Verify CAN bus termination
Ensure the two 120-Ohm termination resistors are present and correctly installed at each end of the CAN bus network.
Address specific codes
If a specific code is present, follow the recommended repair actions from the service manual. For a generic CAN bus defect, this involves checking the entire bus.
Isolate faulty modules
If the error persists, disconnect non-essential control units from the CAN network one by one to see if communication is restored, which helps pinpoint a faulty ECU.
Check for mismatched components
On modified machines (e.g., converted to "Speedster" spec), ensure components like the hydraulic pump and ECM are compatible. Reprogramming or swapping the ECM and its data card may be necessary.
Replace faulty components
If a specific module (such as the HBM or ECM) is identified as the source of the fault, replace it with a compatible unit. Genuine AGCO parts are recommended for Valtra repairs.
Consult service manuals
Valtra service manuals provide detailed troubleshooting guides, wiring diagrams, and component locations essential for diagnosing these faults.
Parts you might need
(4)Hydraulic Brake Module (HBM) / Module A45
Part numbers are specific to the machine's serial number
Electronic Control Module (ECM)
0133616Fits Lexion 480R
Electronic Control Module (ECM)
0146434Fits Lexion 500 series models
Control Module
0160550Fits Lexion 550 and 580 models
Get help to fix this fault by requesting a quote