A312

Valtra A312: A1A3/2 Gearbox Oil Temperature Value (Sensor B14) Impossible (Below -50°C)

Issue description

The A1A3/2 Gearbox oil temperature value reported by sensor B14 is impossible, as it is below -50°C. This indicates a fault with the sensor or its wiring.

Check the cause

  1. Sensor B14

  2. Wiring 3 ge 370/11

  3. Wiring 370/23

Repair steps

  1. Inspect

    Inspect sensor B14 for damage or improper installation.

  2. Test

    Test the wiring 3 ge 370/11 for continuity and proper connection.

  3. Test

    Test the wiring 370/23 for continuity and proper connection.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other Valtra codes