Valtra A312: A1A3/2 Gearbox Oil Temperature Value (Sensor B14) Impossible (Below -50°C)
Issue description
The A1A3/2 Gearbox oil temperature value reported by sensor B14 is impossible, as it is below -50°C. This indicates a fault with the sensor or its wiring.
Check the cause
Sensor B14
Wiring 3 ge 370/11
Wiring 370/23
Repair steps
Inspect
Inspect sensor B14 for damage or improper installation.
Test
Test the wiring 3 ge 370/11 for continuity and proper connection.
Test
Test the wiring 370/23 for continuity and proper connection.
Parts you might need
(0)Get help to fix this fault by requesting a quote