Material Note
phosphorsäureesterfrei
Cover Material
Zink-Druckguss, pulverbeschichtet
Fastening Type
mit Durchgangsbohrung für Schraube M6
Flange Material
Zinc pressure cast, nickel-plated
Screws Material
Nickel-plated steel
Housing Material
Aluminium
Module Parameter
Verhalten im Fehlerzustand
Shock Resistance
Shock test with degree of severity 2 to FN 942017-5 and EN 60068-2-27
Diagnosis Via LED
Spannungsversorgung Last
Max. Power Supply
2 x 16 A (externe Sicherung erforderlich)
Relative Humidity
Not condensing
Electrical Controls
Fieldbus
Internal Cycle Time
< 1 ms
Dimensions W x L x H
70,5 mm x 160,65 mm x 102,6 mm
Fuse (Short Circuit)
Internal electronic fuse Per valve outlet
Oscillation Strength
Transport use test with severity level 2 to FN 942017-4 and EN 60068-2-6
Max. Setup Height (m)
3.500
Module Code (Hex/dec)
0x3045/12357d
LABS (PWIS) Conformity
VDMA24364-B2-L
Nominal Altitude Of Use
<= 2000 m ASL (> 79,5 kPa)
Voltage Supply, Function
Elektronik/Sensoren und Last kommend und Funktionserde
Ambient Temperature (°C)
-20 to 50
Bearing Temperature (°C)
-20 to 70
Switch On Valve Terminals
Typ 45, VTSA-F
Max. Number Of Valve Coils
32
Reverse Polarity Protection
yes
Power Blackout Bridging (ms)
10
Power Transmission, Function
Elektronik/Sensoren und Last gehend und Funktionserde
Corrosion Resistance Class KBK
0 - No corrosion stressing
Max. Number Of Valve Positions
32 bei monostabilen Ventilen
Voltage Supply, Connection Type
Plug
Power Supply, Connection Pattern
997378
Power Transmission, Plug Pattern
997378
Communication Interface, Protocol
AP
Power Transmission, Connection Type
socket / container / ….
Voltage Supply, Connection Technology
Push-Pull nach IEC 61076-3-126
Voltage Supply, Number Of Poles/wires
5
Diagnostics Per Internal Communication
Unterspannung Last
Permissible Voltage Fluctuation Of Load
± 10 %
Nominal Operating Voltage DC Of Load (V)
24
Power Transmission, Number Of Pins/wires
5
Power Transmission, Connection Technology
Push-Pull nach IEC 61076-3-126
Intrinsic Power Input Operating Voltage Load
typisch 17 mA
Undervoltage Load/valves (Diagnostic Message) (V)
21,6
Permitted Voltage Oscillations Electronics/sensors
± 25 %
Nominal Operating Voltage DC Electronics / Sensor (V)
24
Intrinsic Power Input Operating Voltage Electronics/sensors
typisch 27 mA
Potential Separation Between The Supply Voltages Electronics/sensor Technology And Load/valves
yes