Overlap
negative Überdeckung
Reset Mode
Mechanical spring
Control Type
pilot operated
Material Note
RoHs compliant
Control Medium
Compressed air to ISO 8573-1:2010 [7:4:4]
Fastening Type
mit Durchgangsbohrung für Schraube M4
Flow Direction
Not reversible
Valve Function
6/2-Wegeventil, monostabil
Screws Material
Stahl, chemisch vernickelt
Exhaust Function
Cannot be throttled
Housing Material
Aluminium wrought alloy
Operating Medium
Compressed air to ISO 8573-1:2010 [7:4:4]
Shock Resistance
Shock test with degree of severity 2 to FN 942017-5 and EN 60068-2-27
Control Air Supply
external
Construction Set Up
Piston pusher
Complies To Standard
EN 60947-5-2
Oscillation Strength
Transport use test with severity level 2 to FN 942017-4 and EN 60068-2-6
Electrical Connection
Plug
Hand Assist Actuation
Covered
Installation Position
arbitrary
Measurement Principle
Inductive
Control Pressure (MPa)
0,35 to 0,8
LABS (PWIS) Conformity
VDMA24364-Zone III
Noise Status Indicator
LED
Pneumatic Connection 1
G1/8
Pneumatic Connection 2
G1/8
Pneumatic Connection 3
G1/8
Pneumatic Connection 4
G1/8
Pneumatic Connection 5
G1/8
Pneumatic Connection 6
G1/8
Residual Ripple Sensor
± 10 %
Nominal Altitude Of Use
1000 m to VDE 0580
Medium Temperature (°C)
50
Operating Pressure (MPa)
0 to 1
Signal Condition Display
LED gelb, Ventilansteuerung
Switching Position Query
Idle position with sensor
Ambient Temperature (°C)
-5 to 50
Bearing Temperature (°C)
60
Control Air 14 Connection
M5
Switching Element Function
NC contact
Switching Position Display
LED
Reverse Polarity Protection
for all electrical connections
Sound Pressure Level (dB(A))
64
Corrosion Resistance Class KBK
2 - moderate corrosion stress
Operating Voltage Range DC (V)
24
Permitted Voltage Oscillations
-10%
Max. Output Current Sensor (mA)
200
Short Circuit Resistance Sensor
yes
Nominal Operating Voltage DC (V)
24
Reverse Polarity Protection Sensor
for all electrical connections
Max. Switching Frequency Sensor (Hz)
5.000
Note On Operating And Control Medium
Oiled operation not possible
Operating Voltage Range DC Sensor (V)
10 to 30
Valve - Sensor Switching Time On (ms)
11
Max. Positive Test Impulse At 0 Signal
800
Valve - Sensor Switching Time Off (ms)
70
Max. Negative Test Impulse For 1 Signal
400
Protect Against Direct And Indirect Contact
PELV
UKCA Marking (See Declaration Of Conformity)
nach UK RoHS Vorschriften
CE Certificate (See Declaration Of Conformity)
nach EU-RoHS-Richtlinie
Nominal Flow Rate Standardised According To ISO 8778
830
Standard Nominal Flow Rate (Standardised To DIN 1343)
770
Cleanroom Suitability, Measured According To ISO 14644-14
Klasse 5 nach ISO 14644-1