Overlap
positive Überdeckung
Permission
C-tick, CSA (OL), c UL us - Recognized (OL)
Control Type
pilot operated
Fastening Type
on connection plate
Valve Function
5/2 monostable
Screws Material
Zinc-plated steel
Exhaust Function
drosselbar, über Drosselplatte, über Einzelanschlussplatte
Housing Material
PA, Aluminium die casting
Operating Medium
Compressed air to ISO 8573-1:2010 [7:4:4]
Shock Resistance
Shock test with degree of severity 2 to FN 942017-5 and EN 60068-2-27
Sensor Connection
2.5 m, cable
Control Air Supply
external
Construction Set Up
Piston pusher
Protection Category
IP65, NEMA 4
Material Information
RoHs compliant
Oscillation Strength
Transport use test with severity level 2 to FN 942017-4 and EN 60068-2-6
Pilot Air Port 12/14
Connection plate Size 26 mm to ISO 15407-2
Empty Run Sensor (mA)
<= 10 mA
Hand Assist Actuation
Covered
Installation Position
arbitrary
Measurement Principle
Inductive
LABS (PWIS) Conformity
4 pin, Plug, to ISO 15407-2
Noise Status Indicator
LED
Pneumatic Connection 1
Connection plate Size 26 mm to ISO 15407-2
Pneumatic Connection 2
Connection plate Size 26 mm to ISO 15407-2
Pneumatic Connection 3
Connection plate Size 26 mm to ISO 15407-2
Pneumatic Connection 5
Connection plate Size 26 mm to ISO 15407-2
Residual Ripple Sensor
± 10 %
Sensor Voltage Drop (V)
<= 2 V
Medium Temperature (°C)
-5 to 50
Operating Pressure (bar)
-0.9 to 10
Signal Condition Display
LED
Switching Position Query
Idle position with sensor
Ambient Temperature (°C)
-5 to 50
Coil Characteristic Value
24 V DC: 1,6 W
Switching Element Function
NC contact
Surge Voltage Strength (kV)
2,5
Sound Pressure Level (dB(A))
85
Corrosion Resistance Class KBK
0 - No corrosion stressing
Permitted Voltage Oscillations
± 10 %
Max. Output Current Sensor (mA)
200
Short Circuit Resistance Sensor
Cycling
Exhaust Control Connection 82/84
Not recorded, Selectively:, Recorded
Nominal Operating Voltage DC (V)
24
Reverse Polarity Protection Sensor
for all electrical connections
Max. Switching Frequency Sensor (Hz)
5.000
Support Air Control Connection 12/14
Connection plate Size 26 mm to ISO 15407-2
Operating Voltage Range DC Sensor (V)
10 to 30
Valve - Sensor Switching Time Off (ms)
11
Flow Valve Pneumatically Linked (l/min)
1.100
Flow Valve Single Connection Plate (l/min)
1.200
Max. Tightening Torque Valve Fastening (Nm)
1.8 to 2.2
Max. Positive Test Impulse At 0 Signal (µs)
1.200
Max. Negative Test Impulse For 1 Signal (µs)
1.100
CE Certificate (See Declaration Of Conformity)
to EU EMC directive
Information About Operating And Control Medium
Oiled operation possible (required in further operations)
Flow Valve Pneumatically Linked Flow Optimised (l/min)
1.350
Standard Nominal Flow Rate (Standardised To DIN 1343) (l/min)
1.100