Permission
C-tick, c CSA us (OL), c UL us - Recognized (OL)
Control Type
pilot operated
Fastening Type
on connection plate
Flow Direction
Exclusively reversible
Seals Material
FKM, HNBR, NBR
Valve Function
2x3/2 closed monostable
Screws Material
Zinc-plated steel
Exhaust Function
drosselbar, über Drosselplatte, über Einzelanschlussplatte
Housing Material
PA, Aluminium die casting
Operating Medium
Compressed air to ISO 8573-1:2010 [7:4:4]
Shock Resistance
Shock test with degree of severity 2 to FN 942017-5 and EN 60068-2-27
Control Air Supply
external
Construction Set Up
Piston pusher
Protection Category
IP65, NEMA 4
Complies To Standard
ISO 5599-2
Material Information
RoHs compliant
Oscillation Strength
Transport use test with severity level 2 to FN 942017-4 and EN 60068-2-6
Pilot Air Port 12/14
Connection plate Size 2 to ISO 5599-2
Hand Assist Actuation
Covered
Installation Position
arbitrary
LABS (PWIS) Conformity
Plug-in, to ISO 5599-2
Pneumatic Connection 1
Connection plate Size 2 to ISO 5599-2
Pneumatic Connection 2
Connection plate Size 2 to ISO 5599-2
Pneumatic Connection 3
Connection plate Size 2 to ISO 5599-2
Pneumatic Connection 5
Connection plate Size 2 to ISO 5599-2
Medium Temperature (°C)
-5 to 50
Operating Pressure (bar)
-0.9 to 10
Signal Condition Display
LED
Ambient Temperature (°C)
-5 to 50
Coil Characteristic Value
24 V DC: 4,6 W
Surge Voltage Strength (kV)
2,5
Corrosion Resistance Class KBK
0 - No corrosion stressing
Permitted Voltage Oscillations
± 10 %
Exhaust Control Connection 82/84
Selectively:, Recorded, Not recorded to standard
Support Air Control Connection 12/14
Connection plate Size 2 to ISO 5599-2
Nominal Current For Current Reduction
35 mA after 30 ms
Flow Valve Pneumatically Linked (l/min)
2.400
Nominal Tightening Current Per Solenoid
165 mA to 30 ms
Flow Valve Single Connection Plate (l/min)
2.600
Max. Positive Test Impulse At 0 Signal (µs)
1.000
Max. Negative Test Impulse For 1 Signal (µs)
3.500
CE Certificate (See Declaration Of Conformity)
to EU EMC directive
Information About Operating And Control Medium
Oiled operation possible (required in further operations)
Standard Nominal Flow Rate (Standardised To DIN 1343) (l/min)
2.400