Festo - VSVA-B-T32W-AZ-D1-1T1L-8034835 - Solenoid Valve

SKU: festo-vsva-b-t32w-az-d1-1t1l-8034835

Festo - VSVA-B-T32W-AZ-D1-1T1L-8034835 - Solenoid Valve

€253.38€216.56 (Excl. VAT)

Available for backorder – we will confirm the soonest available delivery date within 1 business day after ordering

Shipping fee: €9.99 incl. VAT

Pay Securely with

Price

€253.38

Brand
Permission
CSA (OL), c UL us - Recognized (OL)
Control Type
pilot operated
Actuation Type
Electrical
Fastening Type
on connection plate
Flow Direction
Exclusively reversible
Seals Material
FKM, HNBR, NBR
Valve Function
2x3/2 open/closed monostable
Screws Material
Zinc-plated steel
Build Width (mm)
42
Exhaust Function
drosselbar, über Drosselplatte, über Einzelanschlussplatte
Housing Material
PA, Aluminium die casting
Operating Medium
Compressed air to ISO 8573-1:2010 [7:4:4]
Shock Resistance
Shock test with degree of severity 2 to FN 942017-5 and EN 60068-2-27
Sealing Principle
Soft
Control Air Supply
external
Flow Valve (l/min)
1.400
Construction Set Up
Piston pusher
Protection Category
IP65, NEMA 4
Material Information
RoHs compliant
Oscillation Strength
Transport use test with severity level 2 to FN 942017-4 and EN 60068-2-6
Pilot Air Port 12/14
Connection plate Size 1 to ISO 5599-2
Hand Assist Actuation
Covered
Installation Position
arbitrary
Shifting Time On (ms)
34
LABS (PWIS) Conformity
Plug-in, to ISO 5599-2
Pneumatic Connection 1
Connection plate Size 1 to ISO 5599-2
Pneumatic Connection 2
Connection plate Size 1 to ISO 5599-2
Pneumatic Connection 3
Connection plate Size 1 to ISO 5599-2
Pneumatic Connection 5
Connection plate Size 1 to ISO 5599-2
Shifting Time Off (ms)
28
Degree Of Contamination
3
Operating Pressure (bar)
-0.9 to 10
Signal Condition Display
LED
Ambient Temperature (°C)
-5 to 50
Coil Characteristic Value
24 V DC: 1,3 W
Surge Voltage Strength (kV)
2,5
Corrosion Resistance Class KBK
0 - No corrosion stressing
Permitted Voltage Oscillations
± 10 %
Exhaust Control Connection 82/84
Selectively:, Recorded, Not recorded to standard
Support Air Control Connection 12/14
Connection plate Size 1 to ISO 5599-2
Flow Valve Pneumatically Linked (l/min)
1.200
Nominal Tightening Current Per Solenoid
60 mA to 30 ms
Flow Valve Single Connection Plate (l/min)
1.200
Max. Positive Test Impulse At 0 Signal (µs)
1.600
Max. Negative Test Impulse For 1 Signal (µs)
1.100
Information About Operating And Control Medium
Oiled operation possible (required in further operations)
0 - 90 %
Flow Valve Pneumatically Linked Flow Optimised (l/min)
1.300
Standard Nominal Flow Rate (Standardised To DIN 1343) (l/min)
1.200
EAN
4052568284091
Manufacturer

Be the first to write a review!