Merlo 238 – Main Machine Control System / MERLIN / MCSS / ECU: Calibration Required in 'KG' Menu
Issue description
The system indicates that calibration is required in the 'KG' menu. This is a procedural instruction rather than a component fault, notifying the operator that the weight sensors (load cells) for the tip-over prevention and load monitoring system are not calibrated and require a calibration routine to function correctly.
Applies to these machines
4 machines- Roto
- Turbofarmer
- Panoramic
- Multifarmer
Check the cause
Inspect the wiring harness and connectors leading to the weight sensors (load cells) for any signs of damage, corrosion, or loose connections
Visually inspect the load cells for mechanical damage
On outrigger-equipped models, inspect the bumper pads located between the sensor and the cylinder, as degradation can cause inaccurate readings
Check for any other active fault codes, particularly CAN bus or sensor-related codes, which could interfere with the calibration process
Repair steps
Access diagnostics menu
Access the machine's diagnostics menu. This typically requires using a diagnostic key or pressing and holding the 'MENU' key on the display.
Navigate to calibration
From the main diagnostics or service menu, locate and select the calibration option. This may be indicated by a symbol.
Select 'CAL Kg'
Choose the specific calibration procedure for the weight sensors on the lift cylinder, usually labeled as 'CAL Kg' or a similar symbol.
Perform calibration sequence
Follow the on-screen instructions provided by the machine's display. Ensure the machine is on level ground with no load on the forks. You may be prompted to place a known weight on the forks and move the boom through a specific sequence of positions (e.g., fully retracted, fully extended, at certain angles).
Save and exit
Once the procedure is complete, save the new calibration values and exit the menu. The fault code should clear.
Parts you might need
(5)Headstock Weigh Load Headstock Sensor
079464Confirm correct part number using machine VIN or serial number before ordering
Outrigger Strain Gauge Load Cell
M1476PGA Technika part number. Confirm correct part number using machine VIN or serial number before ordering
- Sensor120143
Generic sensor part. Confirm correct part number using machine VIN or serial number before ordering
Sensor parts
134878Generic sensor parts. Confirm correct part number using machine VIN or serial number before ordering
Load Cell Sensor Bumper Pad
M1802PGA Technika part number. Confirm correct part number using machine VIN or serial number before ordering
Get help to fix this fault by requesting a quote