001-03
New Holland 001-03: Hydraulic Charge Pressure Switch Shorted to High Source
Issue description
The hydraulic charge pressure switch is experiencing a short to high, which may affect the proper operation of the hydraulic system. This condition indicates an electrical fault in the circuit associated with the hydraulic charge pressure switch.
Check the cause
The wiring and connections of the hydraulic charge pressure switch
The integrity of the circuit associated with the hydraulic charge pressure switch
Repair steps
Inspect
Inspect the wiring and connections of the hydraulic charge pressure switch for damage, wear, or improper connections.
Test
Test the circuit associated with the hydraulic charge pressure switch for continuity and proper voltage levels.
Parts you might need
(0)Get help to fix this fault by requesting a quote