New Holland 1027 – Armrest Controller (ARU) / Hitch Controller (ATC) / Electronic Draft Control (EDC) Module: Not Implemented / Lift Arm Position Voltage Low
Issue description
In newer CAN-bus systems, indicates a software configuration or communication mismatch where a controller receives a signal for an unsupported feature. In older EDC systems, indicates the maximum lift arm position potentiometer voltage is too low, pointing to a physical electrical failure.
Applies to these machines
5 machines- New Holland T8.xxx Series
- New Holland T6 Series
- New Holland T7 Series
- New Holland TM Series
- New Holland MXM Series
Check the cause
For 'Not Implemented' (Configuration Issue): Verify if any new switches, joysticks, or sensors were recently installed or replaced in the cab/armrest.
For 'Not Implemented' (Configuration Issue): Check the tractor's software configuration to ensure the Armrest controller settings match the physical hardware.
For 'Not Implemented' (Configuration Issue): Check the CAN data bus for communication loss between the Armrest and Hitch controllers.
For 'Lift Arm Position' (Electrical Issue): Inspect the wiring harness leading to the rear lift arm position sensor for chafing, pinched wires, or a short to ground.
For 'Lift Arm Position' (Electrical Issue): Disconnect the sensor and use a multimeter to verify a steady 5V reference and a good ground at the connector.
For 'Lift Arm Position' (Electrical Issue): Measure the resistance sweep of the potentiometer while manually moving the lift arms to check for dead spots.
Repair steps
Connect diagnostic tool
For 'Not Implemented': Connect the CNH Electronic Service Tool (EST) to the tractor's diagnostic port.
Navigate to configurations
For 'Not Implemented': Navigate to the Armrest Controller (ARU) and Hitch Controller configurations.
Review and disable options
For 'Not Implemented': Review the installed options. If a feature (like a specific remote switch or draft pin) is enabled in the software but not physically present on the tractor, disable it in the configuration.
Perform module configuration
For 'Not Implemented': If a new controller was recently installed, perform a complete module configuration and calibration to match the tractor's build sheet.
Clear fault codes
For 'Not Implemented': Clear the fault codes and cycle the key to verify the code does not return.
Locate potentiometer
For 'Lift Arm Position Voltage Low': Locate the lift arm position potentiometer on the rear rockshaft/linkage.
Remove faulty sensor
For 'Lift Arm Position Voltage Low': If the 5V reference and ground are good but the signal voltage is out of range (too low), remove the faulty sensor.
Install new sensor
For 'Lift Arm Position Voltage Low': Install the new lift arm position sensor, ensuring the mechanical drive element/linkage is properly aligned.
Reconnect wiring
For 'Lift Arm Position Voltage Low': Reconnect the wiring harness.
Perform autocalibration
For 'Lift Arm Position Voltage Low': You must perform a Hydraulic Lift Autocalibration (often associated with code 1024) after replacing the sensor so the EDC module learns the new minimum and maximum voltage limits.
Parts you might need
(2)Lift Arm Position Sensor / Rear Linkage Potentiometer
06350969Rear linkage potentiometer for various CNH applications
Left-Hand Lift Arm Assembly
47125529Includes the lift arm position sensor drive element and bushing for installation
Get help to fix this fault by requesting a quote