New Holland 103.07: Twine Potentiometer Range Out of Range Above Minimum
Issue description
The twine potentiometer is reporting a range that is outside the expected limits, specifically exceeding the minimum threshold. This indicates a potential issue with the sensor's output or its connection.
Check the cause
Twine potentiometer wiring
Twine potentiometer signal output
Connection between the twine potentiometer and the controller
Repair steps
Inspect
Inspect the wiring and connections of the twine potentiometer for damage, corrosion, or loose contacts.
Test
Test the signal output of the twine potentiometer using a multimeter or diagnostic tool to verify it is within the expected range.
Calibrate
If the signal is out of range, attempt to recalibrate the twine potentiometer according to the manufacturer's instructions.
Parts you might need
(0)Get help to fix this fault by requesting a quote