1045
New Holland 1045 – IC: Fuel Level Monitoring: Open Circuit
Issue description
The system has detected an open circuit in the fuel level monitoring system. This indicates a break or disconnection in the wiring or connection related to the fuel level monitoring.
Check the cause
Fuel level sensor wiring
Fuel level sensor connection
Wiring harness for continuity
Repair steps
Inspect
Inspect the wiring and connections related to the fuel level monitoring for any visible damage, disconnection, or corrosion.
Test
Test the continuity of the wiring harness using a multimeter to identify any open circuits.
Repair
Repair or replace any damaged wiring, connectors, or components identified during inspection and testing.
Parts you might need
(0)Get help to fix this fault by requesting a quote