1045

New Holland 1045 – IC: Fuel Level Monitoring: Open Circuit

Issue description

The system has detected an open circuit in the fuel level monitoring system. This indicates a break or disconnection in the wiring or connection related to the fuel level monitoring.

Check the cause

  1. Fuel level sensor wiring

  2. Fuel level sensor connection

  3. Wiring harness for continuity

Repair steps

  1. Inspect

    Inspect the wiring and connections related to the fuel level monitoring for any visible damage, disconnection, or corrosion.

  2. Test

    Test the continuity of the wiring harness using a multimeter to identify any open circuits.

  3. Repair

    Repair or replace any damaged wiring, connectors, or components identified during inspection and testing.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes