1059

New Holland 1059: Working Arm Hitch Electronic Draft Control Diagnostic Error

Issue description

The system has detected a diagnostic error related to the Working Arm Hitch Electronic Draft Control. The specific issue is a connection or electrical open circuit, along with an 8 Volt reference error associated with the Draft Load Pins.

Check the cause

  1. The connection and wiring related to the Working Arm Hitch Electronic Draft Control

  2. The electrical continuity of the circuit associated with the Draft Load Pins

  3. The 8 Volt reference signal for the Draft Load Pins

Repair steps

  1. Inspect

    Inspect the connection and wiring for the Working Arm Hitch Electronic Draft Control for any signs of damage, looseness, or disconnection.

  2. Test

    Test the electrical continuity of the circuit associated with the Draft Load Pins using a multimeter or appropriate testing equipment.

  3. Verify

    Verify the 8 Volt reference signal for the Draft Load Pins to ensure it is within the expected range as specified in the service manual.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes