New Holland 1066 – EDC: Lifting Control Solenoid Valve Shorted
Issue description
The Electronic Draft Control (EDC) module has detected a short circuit in the electrical circuit of the solenoid valve responsible for lifting the hydraulic arms. This condition means electrical current is diverting from its intended path, often to a ground, causing excessive current flow and preventing proper operation of the three-point hitch lifting mechanism.
Applies to these machines
17 machines- TM115
- TM120
- TM125
- TM130
- TM135
- TM140
- TM150
- TM155
- TM165
- 8160
- 8260
- 8360
- 8560
- MXM120
- MXM130
- MXM140
- MXM155
Check the cause
Visually inspect the wiring harness leading to the lift control solenoid on the hydraulic control valve block for chafed, pinched, or melted wires, especially where it may rub against the tractor frame.
Inspect the electrical connector at the solenoid for corrosion, moisture, or loose pins.
Perform a solenoid resistance test: disconnect the electrical connector and measure resistance across the two terminals of the raise solenoid (expected: 6 to 8 Ohms). A reading near 0 Ohms indicates an internal short circuit.
If solenoid resistance is normal (wiring short cause): with the solenoid and EDC controller disconnected, check the power wire for continuity to ground (should be OL/infinite). Also check for a short between the two wires of the solenoid circuit.
Repair steps
Prepare machine for service
Park the tractor on a level surface, lower all implements to the ground, turn off the engine, remove the key, and disconnect the battery.
Locate the solenoid
Find the lift control solenoid on the EDC hydraulic valve block, typically located near the rear of the tractor under the cab or near the three-point hitch assembly.
Replace solenoid (if internally shorted)
If the solenoid resistance reads near 0 Ohms, unscrew the faulty solenoid from the valve body (expect minor fluid loss). Install the new solenoid and torque to manufacturer specifications.
Repair wiring harness (if externally shorted)
If the wiring is shorted to ground or across wires, trace the harness from the solenoid back to the control unit. Repair or replace the damaged section and seal against moisture and abrasion.
Reassemble and clear codes
Reconnect all electrical connectors and the battery. Turn the ignition on and clear stored fault codes using the instrument cluster display or a diagnostic tool.
Test operation
Start the tractor and test the full range of motion of the hydraulic lift to ensure proper operation.
Parts you might need
(2)- EDC Lift Solenoid Valve9970157
Common for TM and 60 series tractors. Verify fitment by serial number.
- EDC Lift Solenoid Valve5168052
Alternative part number found for the 8360 model. Verify fitment by serial number.
Get help to fix this fault by requesting a quote