New Holland 1068 – HHC: Height Limiter Not Set to Maximum During Calibration
Issue description
The calibration process for the header height was unsuccessful or aborted because the control module did not receive the expected signal confirming that the header had reached its maximum physical height. Proper calibration is essential for the automatic header height control to function correctly, allowing the header to maintain a consistent cutting height and float over uneven terrain.
Applies to these machines
7 machines- CR920
- CR970
- CR8.80
- CR9.90
- CX840
- CX880
- TX62
Check the cause
Verify pre-calibration conditions are met: combine parked on level ground, engine running, header attached and level, and no active faults on the Header Height Controller module
Inspect mechanical components for physical obstructions, debris, or damage to the header linkage, sensor arms, and pivot points that might restrict movement
Check electrical connections by inspecting the multi-coupler plug between the combine and the header to ensure it is fully seated and clean
Examine the wiring harness for the height control sensors for any signs of damage, corrosion, or loose connections
Monitor sensor voltage via the combine's diagnostics menu; voltage should change smoothly between 0.5V and 4.5V as the header is raised and lowered
Repair steps
Perform Header Calibration
From the combine's in-cab display, navigate to the 'Calibrations' menu and select 'Header'. Follow the on-screen prompts to pulse the header down switch to establish the ground position, then pulse the header up switch to determine pressure difference and header weight.
Perform Maximum Stubble Height Calibration
Select the 'Maximum Stubble Height' calibration window from the menu. Using the multi-function handle, raise the header to its highest possible position and press 'Enter' to save this position.
Replace Header Height Sensor
If the calibration repeatedly fails and the fault code 1068 persists, replace the header height sensor (rotary potentiometer).