New Holland 1089 – New Holland Electronic Draft Control: Voltage Supply to Hitch Raise and Lower Coils is Below 8 Volts

Issue description

The voltage supply to the hitch raise and lower coils is below the minimum required level of 8 volts. This may result in improper operation of the hitch system.

Check the cause

  1. Voltage supply to the hitch raise and lower coils

  2. Connections and wiring related to the hitch raise and lower coils

  3. Power source and battery condition

Repair steps

  1. Check the voltage supply to the hitch raise and lower coils using a multimeter.

  2. Inspect the connections and wiring for the hitch raise and lower coils for damage, corrosion, or loose contacts.

  3. Verify the condition of the power source and battery to ensure they are providing sufficient voltage.