New Holland 1104 – EDC / CCH: Voltage Supply to Lift and Lower Coils Below 8 V
Issue description
The voltage supplied to the lift and lower coils of the Electronic Draft Control (EDC) system has dropped below the required 8-volt threshold. This low voltage condition prevents the electronic traction control system from properly operating the tractor's three-point hitch, impeding the ability to lift and lower implements.
Applies to these machines
2 machines- T7
- T8
Check the cause
Check battery voltage and charging system health (optimal battery reading is 12.6V; verify that the alternator is functioning correctly and providing a stable charging voltage). Low voltage can trigger ghost codes.
Inspect fuses related to the EDC, hitch controller, or transmission controller (often located near the battery, under the seat, or behind cab panels)
Inspect the wiring harness and connectors leading to the EDC control valve and solenoids for corrosion, damage, or loose connections, including the chassis ground strap
Perform a voltage test at the solenoid's main wiring harness plug with the key on to verify battery voltage is reaching the coil
Perform a resistance test on the disconnected lift and lower solenoids (expected resistance is 6 to 8 Ohms)
Repair steps
Ensure safety
Turn off the tractor and disconnect the battery cables to prevent electrical shorts before beginning work.
Replace blown fuse
If a blown fuse is found, replace it with a new fuse of the exact same amperage rating. If it blows repeatedly, trace the wiring to locate and repair the underlying short circuit.
Repair wiring and connections
Clean or repair any corroded connectors or damaged wires found in the EDC harness. Ensure all connections and the chassis ground strap are secure.
Replace faulty solenoid coil
If the solenoid resistance is outside the 6-8 Ohm range, unscrew and remove the faulty coil from the stem of the hydraulic valve cartridge. Install the new coil, secure it, and reconnect the electrical plug.
Clear codes and test operation
Reconnect the battery, start the tractor, and verify the active fault code has cleared from the instrument cluster. Operate the three-point hitch to confirm lift and lower functions are restored.
Parts you might need
(7)Automotive Blade Fuse (7.5A)
9623776Amperage varies by machine; check fuse panel diagram.
Automotive Blade Fuse (20A)
9804895Amperage varies by machine; check fuse panel diagram.
- Solenoid Coil, 12V51605296
Verify exact part number with dealer using tractor serial number.
Solenoid Coil, 12V
47597411Verify exact part number with dealer using tractor serial number.
- Solenoid Coil, 12V51605298
Verify exact part number with dealer using tractor serial number.
Solenoid Coil, 12V 16W
87433496For various loaders. Verify exact part number with dealer using tractor serial number.
Solenoid Coil, 12V
87726663Verify exact part number with dealer using tractor serial number.
Get help to fix this fault by requesting a quote