115

New Holland 115 – ATC: Evaporator Temperature Sensor Circuit Fault

Issue description

The Automatic Temperature Control (ATC) module has detected that the evaporator temperature sensor signal is outside of its expected range, indicating either an open circuit (a break in the wiring) or a short circuit (unintended connection to power or ground). This fault prevents the proper regulation of the air conditioning system, which can lead to poor cooling performance or the compressor not engaging.

Applies to these machines

  • TG210
  • TG230
  • TG255
  • TG285
  • T7 Series
  • TM Series

Check the cause

  1. Verify active fault codes by accessing the diagnostic mode on the ATC display (on some systems, press the ambient temperature button three times within five seconds)

  2. Check the evaporator coil and cab air filters for dirt or clogs, as restricted airflow can lead to icing and trigger temperature sensor faults

  3. Visually inspect the wiring harness and connectors leading to the evaporator temperature sensor for chafing, breaks, or corrosion, and ensure the connectors at the sensor and control module are clean and securely connected

  4. Test the evaporator temperature sensor (thermistor) resistance and check the circuit for shorts to power/ground or open circuits

Repair steps

  1. Gain access to the evaporator

    Locate the evaporator and its temperature sensor within the HVAC housing, typically under the cab roof or behind the operator's seat. Remove panels or the cab headliner as needed.

  2. Disconnect and test the sensor

    Disconnect the electrical connector. Using a multimeter set to Ohms, measure the sensor's resistance and compare it to the service manual specifications. If the reading is infinite (open), zero (shorted), or does not match ambient temperature expectations, the sensor is faulty.

  3. Test the wiring for open circuits

    With the sensor disconnected and the key on, check for a 5V reference voltage at the sensor connector. A lack of voltage indicates a break in the wire between the control module and the sensor.

  4. Test the wiring for short circuits

    Check for continuity between each wire in the sensor connector and chassis ground. There should be no continuity on the signal and reference voltage wires. Continuity indicates a short to ground in the harness.

  5. Replace faulty components

    Replace the evaporator temperature sensor if it failed the resistance test, or repair/replace the damaged section of the wiring harness if electrical tests failed.

  6. Reassemble and clear codes

    After replacing the faulty component, reassemble all removed parts. Start the tractor and use the ATC control panel to clear the fault codes.

  7. Verify repair

    Operate the air conditioning system to ensure it is functioning correctly and that the fault code does not return.