116

New Holland 116 – New Holland Automatic Temperature Control Atc: Evaporator temperature sensor shorted to ground

Issue description

The evaporator temperature sensor is experiencing a short to ground, which can cause incorrect temperature readings and affect the operation of the automatic temperature control system.

Check the cause

  1. Evaporator temperature sensor wiring

  2. Evaporator temperature sensor connector

  3. Evaporator temperature sensor itself

Repair steps

  1. Inspect

    Inspect the wiring of the evaporator temperature sensor for any signs of damage, wear, or contact with grounded components.

  2. Inspect

    Check the connector of the evaporator temperature sensor for corrosion, loose connections, or physical damage.

  3. Test

    Test the evaporator temperature sensor for a short to ground using a multimeter, following the procedure outlined in the service manual.

  4. Replace

    If the evaporator temperature sensor is found to be faulty, replace it with a new one as specified by the service manual.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes