12018
New Holland 12018: Too High Current of Electric Motor
Issue description
The system has detected an abnormal level of current flowing through the electric motor. This condition may indicate an overload or a fault within the motor's operation.
Check the cause
Electric motor
Power supply circuit
Circuit connections
Repair steps
Inspect
Inspect the electric motor for signs of damage or overheating.
Test
Test the power supply circuit for proper voltage and current output.
Check
Check all circuit connections for looseness, corrosion, or damage.
Parts you might need
(0)Get help to fix this fault by requesting a quote