12505
New Holland 12505: Air Pressure Sensor Circuit 2 Short Circuit to Power Supply
Issue description
A short circuit has been detected in the air pressure sensor circuit 2 located in the rear axle. This fault indicates an electrical issue within the circuit that is connected to the power supply.
Check the cause
The wiring of the air pressure sensor (circuit 2) in the rear axle
Connections and insulation of the circuit
The power supply line for the air pressure sensor (circuit 2)
Repair steps
Inspect
Inspect the wiring of the air pressure sensor (circuit 2) in the rear axle for damage or wear.
Check
Check the connections and insulation of the circuit for any signs of fault.
Test
Test the power supply line for the air pressure sensor (circuit 2) to identify the source of the short circuit.
Parts you might need
(0)Get help to fix this fault by requesting a quote