12505

New Holland 12505: Air Pressure Sensor Circuit 2 Short Circuit to Power Supply

Issue description

A short circuit has been detected in the air pressure sensor circuit 2 located in the rear axle. This fault indicates an electrical issue within the circuit that is connected to the power supply.

Check the cause

  1. The wiring of the air pressure sensor (circuit 2) in the rear axle

  2. Connections and insulation of the circuit

  3. The power supply line for the air pressure sensor (circuit 2)

Repair steps

  1. Inspect

    Inspect the wiring of the air pressure sensor (circuit 2) in the rear axle for damage or wear.

  2. Check

    Check the connections and insulation of the circuit for any signs of fault.

  3. Test

    Test the power supply line for the air pressure sensor (circuit 2) to identify the source of the short circuit.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes