126
New Holland 126: Short Circuit to Ground on the Input Side of the High Pressure Sensor
Issue description
A short circuit to ground has been detected on the input side of the high pressure sensor. This condition may affect the proper operation of the sensor and the system it is part of.
Check the cause
The wiring and connections associated with the high pressure sensor
The integrity of the input side of the high pressure sensor
The surrounding circuitry for signs of damage or wear
Repair steps
Inspect
Inspect the wiring and connections of the high pressure sensor for damage, wear, or improper connections.
Test
Test the input side of the high pressure sensor for continuity and resistance using a multimeter.
Replace
If a fault is found, replace the affected component identified by this code.
Parts you might need
(0)Get help to fix this fault by requesting a quote