128
New Holland 128 – ATC: High Pressure Switch Input Shorted to Ground
Issue description
The high pressure switch input is experiencing a short to ground, which may cause improper operation of the system it is monitoring.
Check the cause
High pressure switch wiring
High pressure switch connector
Wiring harness for damage or wear
Repair steps
Inspect
Inspect the high pressure switch wiring for any signs of damage, wear, or contact with grounded surfaces.
Inspect
Check the high pressure switch connector for corrosion, loose connections, or physical damage.
Test
Use a multimeter to test the high pressure switch input for a short to ground.
Repair
If a short is found, repair or replace the affected wiring or connector as needed.