New Holland 130: Short Circuit on Power Supply Side of Low-Pressure Switch Input
Issue description
A short circuit has been detected on the power supply side of the low-pressure switch input. This fault indicates an electrical issue that may affect the proper operation of the low-pressure switch.
Check the cause
The wiring connected to the low-pressure switch input
The connections on the power supply side of the low-pressure switch input
The integrity of the circuit leading to the low-pressure switch input
Repair steps
Inspect
Inspect the wiring and connections on the power supply side of the low-pressure switch input for damage, wear, or improper contact.
Test
Test the circuit for continuity and resistance using a multimeter to identify the presence of a short.
Repair
If a short is found, repair or replace the damaged wiring or connections as necessary.
Parts you might need
(0)Get help to fix this fault by requesting a quote