14015

New Holland 14015 – ADIC: ADIC 5 Volt Reference Voltage Too Low

Issue description

The instrument cluster generates its own 5-volt power supply (reference voltage) to power various sensors throughout the machine. This code triggers when the voltage on this reference circuit drops below the 4-volt threshold. This condition is typically caused by a short to ground in the sensor wiring, a shorted sensor pulling the voltage down, or an internal failure of the instrument cluster's power supply.

Applies to these machines

  • T5.95
  • T5.100
  • T5.105
  • T5.110
  • T5.115
  • T5.120 Electro Command
  • T5040
  • T5050
  • T5060
  • T5070

Check the cause

  1. Visually inspect the wiring harnesses connected to the instrument cluster and all associated sensors for any signs of damage, such as chafing, melting, or corrosion

  2. Check for other active fault codes related to specific sensors, which can help pinpoint the location of a short circuit

  3. Isolate the fault by disconnecting sensors one by one from the affected 5-volt reference circuit to see if the fault code clears; if the fault disappears after disconnecting a particular sensor, that sensor or its wiring is likely the cause of the short

Repair steps

  1. Confirm the fault

    Using a suitable diagnostic tool, confirm that fault code 14015 is active.

  2. Identify sensors on the circuit

    Consult a service manual with electrical schematics for the specific tractor model to identify all sensors powered by the ADIC 5-volt rail.

  3. Test the circuit and isolate sensors

    With the ignition on, use a multimeter to measure the voltage on the 5-volt reference wire at one of the sensors connected to the ADIC. If the voltage is below 4 volts, begin disconnecting sensors one at a time. After each sensor is disconnected, re-check the voltage. If the voltage returns to 5 volts after disconnecting a sensor, that sensor is likely shorted internally and requires replacement.

  4. Inspect and repair wiring harness

    If disconnecting all sensors does not resolve the low voltage, the issue is likely a short to ground in the wiring harness. Carefully inspect the harness for any damage, repair any damaged wires, and ensure they are properly insulated.

  5. Replace the ADIC module

    If the sensors and wiring have been ruled out, the ADIC module may have an internal fault in its 5-volt power supply. In this case, the instrument cluster itself must be replaced.

Parts you might need

(10)
  • Listed for New Holland T5040, T5050, T5060, and T5070 tractors

  • Genuine CNH part number for a New Holland Instrument Panel

  • Instrument Cluster

    47468235

    Listed for New Holland T5.105 and T5.95 tractors

  • Listed for New Holland T5.105 and T5.95 tractors

  • ADIC Enhanced Keyboard

  • Instrument Cluster / ADIC Module

    47365935

    Various T-Series Clusters

  • Instrument Cluster / ADIC Module

    47688313

    Various T-Series Clusters

  • Instrument Cluster / ADIC Module

    47449815

    Various T-Series Clusters

  • Instrument Cluster / ADIC Module

    86403813R

    Remanufactured Instrument Cluster

  • Older TM-series ADIC

Get help to fix this fault by requesting a quote

Browse other New Holland codes