New Holland 14015 – ADIC: ADIC 5 Volt Reference Voltage Too Low
Issue description
The instrument cluster generates its own 5-volt power supply (reference voltage) to power various sensors throughout the machine. This code triggers when the voltage on this reference circuit drops below the 4-volt threshold. This condition is typically caused by a short to ground in the sensor wiring, a shorted sensor pulling the voltage down, or an internal failure of the instrument cluster's power supply.
Applies to these machines
10 machines- T5.95
- T5.100
- T5.105
- T5.110
- T5.115
- T5.120 Electro Command
- T5040
- T5050
- T5060
- T5070
Check the cause
Visually inspect the wiring harnesses connected to the instrument cluster and all associated sensors for any signs of damage, such as chafing, melting, or corrosion
Check for other active fault codes related to specific sensors, which can help pinpoint the location of a short circuit
Isolate the fault by disconnecting sensors one by one from the affected 5-volt reference circuit to see if the fault code clears; if the fault disappears after disconnecting a particular sensor, that sensor or its wiring is likely the cause of the short
Repair steps
Confirm the fault
Using a suitable diagnostic tool, confirm that fault code 14015 is active.
Identify sensors on the circuit
Consult a service manual with electrical schematics for the specific tractor model to identify all sensors powered by the ADIC 5-volt rail.
Test the circuit and isolate sensors
With the ignition on, use a multimeter to measure the voltage on the 5-volt reference wire at one of the sensors connected to the ADIC. If the voltage is below 4 volts, begin disconnecting sensors one at a time. After each sensor is disconnected, re-check the voltage. If the voltage returns to 5 volts after disconnecting a sensor, that sensor is likely shorted internally and requires replacement.
Inspect and repair wiring harness
If disconnecting all sensors does not resolve the low voltage, the issue is likely a short to ground in the wiring harness. Carefully inspect the harness for any damage, repair any damaged wires, and ensure they are properly insulated.
Replace the ADIC module
If the sensors and wiring have been ruled out, the ADIC module may have an internal fault in its 5-volt power supply. In this case, the instrument cluster itself must be replaced.
Parts you might need
(10)- Instrument Cluster47398352
Listed for New Holland T5040, T5050, T5060, and T5070 tractors
- Instrument Panel47398364
Genuine CNH part number for a New Holland Instrument Panel
Instrument Cluster
47468235Listed for New Holland T5.105 and T5.95 tractors
- Instrument Cluster47887919
Listed for New Holland T5.105 and T5.95 tractors
- Instrument Cluster / ADIC Module47541068
ADIC Enhanced Keyboard
Instrument Cluster / ADIC Module
47365935Various T-Series Clusters
Instrument Cluster / ADIC Module
47688313Various T-Series Clusters
Instrument Cluster / ADIC Module
47449815Various T-Series Clusters
Instrument Cluster / ADIC Module
86403813RRemanufactured Instrument Cluster
- Instrument Cluster / ADIC Module82035717
Older TM-series ADIC
Get help to fix this fault by requesting a quote