14015

New Holland 14015: ADIC 5 Volt Reference Voltage Too Low

Issue description

The ADIC 5 volt reference voltage is below the acceptable threshold, falling below 4 volts. This may affect the proper operation of the system relying on this reference voltage.

Check the cause

  1. Power supply to the ADIC

  2. Wiring and connections related to the ADIC

  3. Voltage output at the ADIC

Repair steps

  1. Check power supply

    Verify that the power supply providing voltage to the ADIC is functioning correctly and delivering the required voltage.

  2. Inspect wiring

    Examine the wiring and connections associated with the ADIC for any damage, loose connections, or corrosion.

  3. Measure voltage

    Use a multimeter to measure the voltage at the ADIC and confirm it is within the specified range.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote