New Holland 14203: Electro-Hydraulic 4WD Engagement/Release Relay Coil Signal Issue
Issue description
A short circuit to +12 V or an open circuit has been detected on the supply signal to the electro-hydraulic 4WD engagement/release relay coil. This fault affects the proper operation of the 4WD system.
Check the cause
The wiring and connections to the electro-hydraulic 4WD engagement/release relay coil
The integrity of the supply signal circuit to the electro-hydraulic 4WD engagement/release relay coil
The condition of the electro-hydraulic 4WD engagement/release relay coil itself
Repair steps
Inspect
Inspect the wiring and connections to the electro-hydraulic 4WD engagement/release relay coil for damage, corrosion, or loose connections.
Test
Test the supply signal circuit to the electro-hydraulic 4WD engagement/release relay coil for continuity and proper voltage.
Replace
If a fault is found, replace the electro-hydraulic 4WD engagement/release relay coil or repair the affected circuit as needed.