14203

New Holland 14203: Electro-Hydraulic 4WD Engagement/Release Relay Coil Signal Issue

Issue description

A short circuit to +12 V or an open circuit has been detected on the supply signal to the electro-hydraulic 4WD engagement/release relay coil. This fault affects the proper operation of the 4WD system.

Check the cause

  1. The wiring and connections to the electro-hydraulic 4WD engagement/release relay coil

  2. The integrity of the supply signal circuit to the electro-hydraulic 4WD engagement/release relay coil

  3. The condition of the electro-hydraulic 4WD engagement/release relay coil itself

Repair steps

  1. Inspect

    Inspect the wiring and connections to the electro-hydraulic 4WD engagement/release relay coil for damage, corrosion, or loose connections.

  2. Test

    Test the supply signal circuit to the electro-hydraulic 4WD engagement/release relay coil for continuity and proper voltage.

  3. Replace

    If a fault is found, replace the electro-hydraulic 4WD engagement/release relay coil or repair the affected circuit as needed.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes