New Holland 16114 – A/C Controller: Outlet Temperature Sensor Shorted to Ground

Issue description

The Air Conditioning (A/C) controller has detected a short circuit to ground (or 'mass') in the outlet temperature sensor's electrical circuit. This sensor is a thermistor that measures the temperature of the air coming out of the HVAC vents. A short to ground means the sensor's signal wire has made an unintended connection to the vehicle's chassis ground, causing the controller to read an abnormally low or zero voltage that falls outside the expected operating range.

Applies to these machines

  • T7.175
  • T7.190
  • T7.210
  • T7.220
  • T7.230
  • T7.235
  • T7.245
  • T7.250
  • T7.260
  • T7.270
  • T7.275
  • T7.315

Check the cause

  1. Visually inspect the wiring harness leading to and from the HVAC unit in the cab roof for chafed, pinched, or melted wires shorting to the frame or metal components

  2. Disconnect the electrical connector at the outlet temperature sensor (if accessible) and the main connector to the A/C control module, and check for corrosion, moisture ingress, or bent/damaged pins

  3. Perform a continuity test using a multimeter between the sensor's signal wire and a known good chassis ground with the sensor and controller disconnected (should be an open circuit)

  4. Test the resistance of the sensor itself; an extremely low or zero resistance reading indicates an internal short within the sensor

Repair steps

  1. Isolate the fault

    Perform the diagnostic checks to determine if the short circuit lies in the wiring harness or internally within the sensor itself.

  2. Repair wiring harness

    If a short is found in the harness, cut out the compromised portion, splice in a new piece of wire of the same gauge, and seal connections with heat-shrink tubing to prevent moisture intrusion.

  3. Replace the sensor

    If the sensor has an internal short, access the HVAC unit, remove the old sensor, and install a new one.

  4. Clear fault codes

    Use a diagnostic tool to clear the stored fault codes from the A/C controller.

  5. Verify operation

    Operate the A/C system and check for the return of the fault code to ensure the repair was successful.

Parts you might need

(9)
  • NTC thermistor probe (alternate part number 86531133)

  • Measures return air temperature in the cab

  • General Temperature Sensor

    8900123435

    Generic CNH/New Holland temperature sensor

  • Outlet Temperature Sensor

    May be part of a larger HVAC component assembly; verify against serial number

  • Common thermistor used in CNH climate control systems

  • Listed for New Holland T8.300

  • HVAC Sensor47877771

    Listed for T8.355 HVAC

  • HVAC Sensor

    51629916

    Listed for T8.355 HVAC

  • HVAC Sensor47667771

    Listed for T8.355 HVAC

Get help to fix this fault by requesting a quote