New Holland 16121 – ACC / ATC: Temperature Select Potentiometer Open or Shorted to Power Plus

Issue description

The Air Conditioning Controller (ACC) or Automatic Temperature Controller (ATC) has detected a voltage reading from the temperature select potentiometer that is outside of its expected range. This indicates an open circuit (no connection) or a short circuit to a positive power source. This electrical fault prevents the system from accurately reading the operator's desired temperature setting, causing the automatic climate control to fail in regulating the cabin temperature.

Applies to these machines

  • T5.115
  • T6.140
  • T6.165
  • T6.175
  • T6010
  • T6020
  • T6030
  • T6040
  • T6050
  • T6060
  • T6070
  • T6080
  • T7.170
  • T7.220
  • T7.235
  • T7.250
  • T7.260
  • T7.270
  • T7030
  • T7040
  • T7050
  • T7060
  • T8.275
  • T8.300
  • T8.320
  • T8.330
  • T8.350
  • T8.360
  • T8.380
  • T8.390
  • T8.410
  • T8.420
  • T8.435
  • T8010
  • T8020
  • T8030
  • T8040
  • T8050
  • TG210
  • TG215
  • TG230
  • TG245
  • TG255
  • TG275
  • TG285
  • TG305
  • TM115
  • TM120
  • TM125
  • TM130
  • TM135
  • TM140
  • TM150
  • TM155
  • TM165
  • TM175
  • TM190
  • T4020
  • T4030
  • T4040
  • T4050

Check the cause

  1. Visually inspect the wiring harness connected to the A/C control panel for any visible damage, chafing, corrosion on the connectors, or loose pins.

  2. Access the diagnostic 'H' menu routines using a service tool (if equipped) to monitor the potentiometer's output value in real-time as the dial is turned, confirming if the signal is erratic or non-responsive.

  3. Perform a potentiometer resistance test: Disconnect the potentiometer and measure resistance (Ohms) between the specified terminals (e.g., green and orange wires). Look for a smooth, linear change in resistance (typically 1.0 kΩ to 3.7 kΩ) as the knob is turned. An infinite reading indicates an open circuit, while a zero reading indicates a short.

  4. Perform a wiring circuit test: With the potentiometer disconnected and key on, check for a 5-volt reference supply and a good ground at the connector harness. Ensure there is no voltage on the signal return wire (which would indicate a short to power). Check continuity of the signal wire back to the ATC/ACC connector.

Repair steps

  1. Disconnect battery

    Disconnect the negative battery terminal to prevent short circuits before beginning any electrical repair.

  2. Access control panel

    Remove the necessary trim and panels to gain access to the rear of the cab's climate control panel where the potentiometer is located.

  3. Remove old potentiometer

    Disconnect the electrical connector. Remove the temperature control knob from the front of the panel, then loosen and remove the retaining nut or screws holding the potentiometer to the assembly.

  4. Install new potentiometer

    Fit the new potentiometer into the control panel and secure it using the original hardware.

  5. Reconnect and reassemble

    Attach the electrical connector to the new potentiometer. Reinstall the control knob and reassemble all dash panels and trim.

  6. Reconnect battery

    Reconnect the negative battery terminal.

  7. Test operation

    Start the tractor and test the full range of the temperature control dial. Verify the A/C system responds correctly and the fault code does not reappear. Perform system calibration if required by the specific machine model.

Parts you might need

(4)
  • OEM part for New Holland T8 and TG series, and Case IH Magnum models.

  • OEM part widely used across New Holland T4, T6, T7, and TM models.

  • OEM part for New Holland T5.115 (replaces part number 84582144).

  • Temperature Select Potentiometer

    QTP-44367

    Aftermarket replacement specified for New Holland T6 and T7 series tractors.

Get help to fix this fault by requesting a quote

Browse other New Holland codes