New Holland 16125 – BCM or HVAC/Cab controller: High Pressure-Low Pressure Switch (+) Input Shorted to Power Plus
Issue description
The control module has detected a short circuit to a power source in the positive input line of the A/C system's high and low-pressure switch. The controller is reading an abnormally high voltage from the switch's signal wire, indicating it is electrically shorted to a power wire. This condition prevents the A/C compressor from engaging, as the controller cannot accurately determine the refrigerant pressure required for safe operation.
Applies to these machines
12 machines- T6.120
- T6.180
- T6010
- T6060
- T7.170
- T7.315
- T7030
- T7060
- T8.320
- T8.380
- T8020
- T8040
Check the cause
Disconnect the tractor's battery to prevent short circuits before inspecting electrical components
Visually inspect the A/C pressure switch (located on the high-pressure line or receiver/drier) and its wiring harness for chafed insulation, melted wires, pinched wires, or corrosion
Test the wiring harness for a short to power: disconnect the switch, turn the key 'on' (engine off), and measure voltage at the signal pin to ground. Battery voltage indicates a harness short
Test the pressure switch for internal failure: with the connector unplugged and system at rest, check for continuity across the switch terminals. 'OL' (Open Line) indicates an open/failed switch
Verify static refrigerant pressure using an A/C manifold gauge set. Compare actual pressure to the expected state of the switch (e.g., continuity expected if pressure is above 45 psi)
Repair steps
Recover refrigerant (if required)
If the pressure switch is not mounted on a Schrader valve, recover the A/C system's refrigerant using certified equipment before removal. Check the service manual to confirm if a Schrader valve is present.
Replace the pressure switch
Unscrew the old switch. Apply a small amount of A/C-compatible oil to the new switch's O-ring, install it, and tighten to the manufacturer's specified torque without overtightening.
Repair wiring harness
If a short was found during diagnostics, carefully repair the damaged wire section using appropriate connectors and heat shrink tubing to ensure a weather-resistant repair.
Evacuate and recharge A/C system
Reconnect the electrical connector. If refrigerant was recovered, evacuate the system with a vacuum pump for at least 30 minutes to remove air and moisture, then recharge with the correct type and amount of refrigerant.
Clear codes and test operation
Reconnect the battery, start the tractor, clear fault codes with a diagnostic tool, and turn on the A/C to verify the compressor engages and cools properly.
Parts you might need
(5)- Low Pressure Switch84419250
OEM CNH part. Features M10-1.25 female thread.
Low Pressure Switch
87323829OEM CNH part. Features M10-1.25 female thread.
Low Pressure Switch
82027898Cross-Reference Part Number. Features M10-1.25 female thread.
- Low Pressure Switch82036401
Cross-Reference Part Number. Features M10-1.25 female thread.
Cross-references to 84275098 and 84152841. Compatible with T6, T7, Puma, Maxxum, and Optum.
Get help to fix this fault by requesting a quote