16128

New Holland 16128: Short Circuit to 'mass' on the (-) input of the high/low pressure sensor

Issue description

A short circuit to 'mass' has been detected on the (-) input of the high/low pressure sensor. This condition may cause improper operation or failure of the sensor, leading to incorrect pressure readings or system malfunctions.

Check the cause

  1. The wiring and connections associated with the (-) input of the high/low pressure sensor

  2. The integrity of the insulation on the wiring leading to the high/low pressure sensor

  3. Potential damage or wear in the circuit that could cause a short to 'mass'

Repair steps

  1. Inspect

    Inspect the wiring and connections for the (-) input of the high/low pressure sensor for signs of damage, wear, or improper routing.

  2. Test

    Use a multimeter to test for continuity and resistance in the circuit to identify any short to 'mass'.

  3. Repair

    If a short is found, repair or replace the damaged wiring or connections as necessary.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote

    Browse other New Holland codes