New Holland 16133 – ATC or Cab Controller: Low Pressure Switch (-) Input Shorted To Ground
Issue description
The control module has detected a short to ground in the negative (-) input circuit of the A/C low-pressure switch. This indicates that the electrical signal from the switch is unexpectedly being routed directly to the vehicle's chassis ground, causing an abnormal reading. Because the low-pressure switch monitors refrigerant pressure to protect the A/C compressor, a short to ground in this circuit will lead to improper operation or disengagement of the air conditioning system.
Applies to these machines
12 machines- T7.170
- T7.185
- T7.200
- T7.210
- T7.220
- T7.235
- T7.250
- T7.260
- T7.270
- T5 Series
- T6 Series
- T8 Series
Check the cause
Visually inspect the wiring harness leading to and from the A/C low-pressure switch for chafing, cuts, or worn insulation making contact with the tractor's frame or metal components
Disconnect the electrical connector from the low-pressure switch and examine the terminals for corrosion, moisture, or pushed-out pins
Check the static pressure of the A/C system to ensure it is not empty, as a failing switch can sometimes indicate an underlying refrigerant leak
Repair steps
Isolate the circuit
With the key in the OFF position, disconnect the electrical connector from the A/C low-pressure switch to determine if the short is within the switch itself or in the wiring harness.
Test the switch
Set a multimeter to the continuity or resistance (Ohms) setting. Connect one probe to the negative (-) terminal of the switch and the other to a known good chassis ground. If the multimeter indicates continuity (near zero Ohms), the switch is internally shorted to ground and must be replaced.
Test the wiring harness
If the switch tests good, the fault lies in the wiring. With the switch disconnected, turn the key to the ON position (do not start the engine). Set the multimeter to measure DC voltage. Connect the black probe to ground and probe the negative (-) input terminal in the harness connector. A reading near zero volts confirms a short to ground in the wiring.
Locate the short
Visually trace the wire from the switch connector back towards the control module, paying close attention to areas near metal components. Perform a continuity test segment by segment if visual inspection is inconclusive.
Repair or replace wiring
Cut out the damaged portion of the wire, splice in a new piece of wire of the same gauge, and seal with heat-shrink tubing. If harness damage is extensive, replace that section of the harness.
Reassemble and test
Reconnect the electrical connector to the low-pressure switch. Clear the fault codes using the tractor's diagnostic menu or service tool. Start the tractor and operate the A/C system to ensure the fault code does not reappear.
Parts you might need
(5)Air Conditioning Low-Pressure Switch
QTP-44302Aftermarket part number for T5, T6, T7, and T8 series. OEM part numbers vary by tractor model and year; verify with a dealer using the serial number.
- A/C Low-Pressure Switch87000228
Verify fitment by serial number
- A/C Low-Pressure Switch84419250
Verify fitment by serial number
- A/C Low-Pressure Switch87356362
Interchangeable with F0NN19E561AA. Verify fitment by serial number
- A/C Low-Pressure Switch47996489
Verify fitment by serial number
Get help to fix this fault by requesting a quote