New Holland 16134: Low Pressure Switch Open for More Than 1 Minute

Issue description

The system has detected that the low pressure switch has been open for a duration exceeding 1 minute. This condition may indicate an issue with the pressure system or the switch itself.

Check the cause

  1. The condition of the low pressure switch

  2. The integrity of the wiring connected to the low pressure switch

  3. The pressure levels in the system

Repair steps

  1. Inspect the low pressure switch

    Check for physical damage, corrosion, or improper installation.

  2. Test the low pressure switch

    Use a multimeter to verify the switch's functionality under different pressure conditions.

  3. Check the system pressure

    Verify that the system is operating within the expected pressure range.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote