New Holland 168 – TMF: PTO ON/OFF Switch Failure in Armrest Controller

Issue description

The PTO ON/OFF switch located in the Armrest Controller has failed. This fault prevents the proper operation of the PTO system, as the switch is not functioning as intended.

Check the cause

  1. PTO ON/OFF switch

  2. Armrest Controller

Repair steps

  1. Inspect

    Visually inspect the PTO ON/OFF switch for physical damage or wear.

  2. Test

    Test the PTO ON/OFF switch for proper electrical continuity and functionality.

  3. Replace

    If the switch is found to be faulty, replace it with a compatible component.

Parts you might need

(0)

    Get help to fix this fault by requesting a quote